KitchenAid W10284348A installation instructions Installation Requirements, Tools and Parts

Page 4

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to wall behind range.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Burner heads and caps

Grill grate (on grill models)

Tools needed

Tape measure

#2 Phillips screwdriver

¹⁄₈" x 4¼" flat-blade screwdriver

Level

Drill

Wrench or pliers

Pipe wrench

Adjustable wrench or ⁵⁄₈" wrench

³⁄₈" drive ratchet

¹⁄₈" drill bit

¹⁵⁄₁₆" combination wrench

¹⁄₄", ³⁄₈", ⁵⁄₁₆" nut drivers

³⁄₁₆" carbide tip masonry bit

Marker or pencil

Pipe-joint compound resistant to LP gas

Noncorrosive leak-detection solution

Tubing cutter

For LP/Natural Gas

Conversions

T15 Torx®† screwdriver

⁷⁄₈" socket

Adjustable wrench

½" deep-well socket

7 mm nut driver

Masking tape

Wave tray (on grill models)

Flame spreader (on grill models)

Burner assembly (on grill models)

Grease trays (2) (on grill models)

Griddle drip tray (on griddle models)

Grill drip tray (on grill models)

Island trim

LP orifice package (W10221288)

Conversion label (W10221320)

NOTE: The cooktop is manufactured for use with Natural gas. To convert to LP gas, see the “Gas Conversions” section.

Additional Parts Supplied on Steam-Assist Models

Model W10049700 water filter kit

¼" to ¼" water supply union

Parts needed

Power supply cord kit:

30" (76.2 cm) and 36" (91.4 cm) models - A UL listed

Parts supplied

Check that all parts are included.

Anti-tip bracket kit

A

B

A.Anti-tip bracket

B.#8-18 x 1" Phillips head screws (4)

NOTE: Anti-tip bracket must be securely mounted to subfloor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store. See “Install Anti-Tip Bracket” section.

Gas pressure regulator

Burner grates

†®TORX is a registered trademark of Acument Intellectual Properties, LLC.

40 amp power supply cord kit

48" (121.9 cm) models - A UL listed 50 amp power supply

cord kit marked for use with nominal 1³⁄₈" (34.93 mm)

diameter connection openings

A UL listed strain relief

UL listed wire connectors

All models must be installed with a backguard if installing at

zero clearance to a combustible backwall. See “Cabinet

Dimensions” in the “Location Requirements” section for

installation requirements.

30" (76.2 cm) Adjustable Backguard

Order Part Number 8285148

36" (91.4 cm) Adjustable Backguard

Order Part Number 8284756

48" (121.9 cm) Adjustable Backguard

Order Part Number 8284755

9" (22.9 cm) Backguard for 30" (76.2 cm) Ranges

Order Part Number W10115773

9" (22.9 cm) Backguard for 36" (91.4 cm) Ranges

Order Part Number W10115776

9" (22.9 cm) Backguard for 48" (121.9 cm) Ranges

Order Part Number W10115777

4

Image 4
Contents Commercial Style Dual Fuel Convection Range W10284348ATable of Contents Range Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsMobile Home Additional Installation Requirements Product Dimensions 30 76.2 cm modelsLocation Requirements High Altitude Conversion36 91.4 cm models Cabinet Dimensions48 121.9 cm models Water Supply Requirements Water Filtration System Location RequirementsElectrical Requirements U.S.A. Only If connecting to a 4-wire system If connecting to a 3-wire systemWire receptacle 14-50R Wire receptacle 10-50RType of Gas Gas Supply RequirementsGas Supply Line Installation Instructions Gas Supply Pressure TestingUnpack Range Gas Pressure RegulatorInstall Optional Backguard Install Anti-Tip Bracket30 76.2 cm and 36 91.4 cm Models Electrical Connection U.S.A. OnlyUL listed strain relief Block screw Power supply cord Wire connection Power supply cordGround-link screw Ground link bent away from range Install Water Filtration System on some models Pipe thread Adapter Flexible connector Make Gas ConnectionComplete Connection Closed valve Open valveVerify Anti-Tip Bracket Location Install Grill Grease TraysLevel Range Install Burner Heads and Caps Install GriddleElectronic Ignition System Initial Lighting and Gas Flame Adjustments To Adjust Flame HeightCheck Operation of Cooktop Burners If burners do not light properlyReinstall Kickplate Complete InstallationIf you need Assistance or Service Check Operation of OvensGas Supply Pressure Testing GAS ConversionsLP Gas Conversion To Convert Gas Pressure RegulatorTo Convert Grill Burner on some models Complete InstallationBurner orifice spud Grill orifice hood Burner cap Burner head Natural Gas ConversionBurner head Gas opening Burner base Size stamp Strip Circuits Cooktop Schematics Wiring DiagramsBurner Cooktop AC Drive Motor Relay Coil Relay Contact 48 121.9 cm Oven Schematic for Kdrs Models Left OvenBKL2 L1 48 121.9 cm Oven Schematic for Kdru Models Left OvenSécurité DE LA Cuisinière Votre sécurité et celle des autres est très importanteExigences D’INSTALLATION Outillage et piècesPièces fournies Outils nécessairesPièces nécessaires Exigences demplacementConversion pour utilisation en haute altitude Modèles de 36 91,4 cm Dimensions du produit Modèles de 30 76,2 cmModèles de 48 121,9 cm Exigences demplacement du système de Filtration de leau Dimensions du placardConfiguration dinstallation typique ½ 3,8 cm J 7,6 cm K 12,7 cmSpécifications de l’installation électrique Spécifications de l’alimentation en eauSpécifications de lalimentation en gaz Alimentation en eau par osmose inverseType de gaz Canalisation de gazDétendeur Débit thermique des brûleurs AltitudeInstructions D’INSTALLATION Installation du dosseret facultatifInstallation de la bride antibasculement Déballage de la cuisinièreInstallation du système de filtration de leau Installation du modèle de filtre à eau W10049700Raccordement à l’alimentation en eau du domicile Raccordement à lentrée du filtre à eau jauneSi lon doit dégager le tuyau Raccordement à la sortie du filtre à eau bleuVérification de lemplacement de la bride Antibasculement Raccordement au gazRéglage de laplomb de la cuisinière Achever le raccordementInstallation des plateaux à graisse du gril Installation de la plaque à frire Installation des têtes et des chapeaux de brûleurSystème dallumage électronique Allumage initial et réglages des flammes de gazSi les brûleurs ne sallument pas correctement Hauteur de flammeRéglage de la taille des flammes Brûleur à double flammeRéinstallation du garde-pieds Achever linstallationSi vous avez besoin d’assistance ou de service Contrôle du fonctionnement du/des foursConversions Pour Changement DE GAZ Conversion pour lalimentation au propaneConversion du détendeur Chapeau de louverture daccès Position LP Joint détanchéitéConversion du brûleur du gril sur certains modèles Conversion des brûleurs de surfaceGicleur de brûleur Injecteur femelle du gril Achever linstallation Conversion pour lalimentation au gaz naturelOuverture de la virole de réglage Vis Chapeau de louverture daccèsChapeau de brûleur Marquage pour identification De la tailleOuverture de gaz Base du brûleur Achever linstallation Schémas des circuits du four Schéma de câblage Schémas de la table de cuissonLégende Tableau de commande Clavier Schéma du four 48 121,9 cm pour les modèles KdrsLégende Schéma du four 48 121,9 cm pour les modèles Kdru Porte du four ferméeAll rights reserved