Installation Instructions
DUCTWORK INSTALLATION
(Note: For planning purposes only.)
6INSTALLING THE DUCTWORK
Use galvanized or aluminum duct in 6″ round or 31⁄4″ x 10″ size, or a combination of both.
PVC duct should be used if installing under a poured concrete slab.
NOTE: Local building code must be followed in specifying approved type and schedule of ALL duct used.
Always use an appropriate roof or wall cap with damper.
Through Cabinet Toe Space |
| Between Floor Joist |
Downward Venting
Install ductwork, making
Duct Tape Over Seam
and Screw
Air Flow
Screw
Use the shortest and straightest duct run possible. For satisfactory performance the duct run should not exceed 100 feet equivalent length. Refer to TABLE 1 of equivalent lengths. Use TABLE 1 to calculate the total equivalent length of the ductwork.
OPTIONAL INSTALLATION:
REAR WALL VENTING
5″ round duct may be used on SHORT DUCT runs of 3 feet or less, such as direct to outside wall venting.
Inside Wall to Roof | Direct to Outside |
Rear Wall Venting
To convert blower exhaust direction, remove four nuts behind the filter which hold blower and wire finger guard.
Rotate blower and reinstall to vent chamber, as shown above. Retighten nuts, but do not overtighten.
22