Rotel RB-1510 user service Input Signal Connections

Page 8

8

RB-1510 Stereo Power Amplifier

Power Switch and Power Indicator 1

The power switch is located on the front panel of your amplifier. To turn the amplifier on, push the switch in. The ring around the switch button will light, indicating that the amplifier is turned on. To turn the amplifier off, push the button again and return it to the out position.

Protection Indicator 2

Thermal and protection circuits protect the amplifier against potential damage in the event of extreme or faulty operating conditions. Unlike many designs, the RB-1510 protection circuit is independent of the audio signal and has no impact on sonic performance. Instead, the protection circuit monitors the temperature of the output devices and shuts down the amplifier if safe limits are exceeded.

In addition, the RB-1510 includes over-current protection which operates only when load impedances drop too low. This protection is independent for each channel and is indicated by the front panel Protection LED.

Should a faulty condition arise, the amplifier channel at fault will stop playing and the Protection LED on the front panel will light.

If this happens, turn the amplifier off, let it cool down for several minutes, and attempt to identify and correct the problem. When you turn the amplifier back on, the protection circuit will automatically reset and the PROTECTION LED should go out.

In most cases, the protection circuitry activates because of a fault condition such as shorted speaker wires, or inadequate ventilation leading to an overheating condition. In very rare cases, highly reactive or extremely low impedance speaker loads could cause the protection circuit to engage.

Note: The Protection Mode LED also lights when the 12V Trigger system is being used and the amplifier is in Standby mode.

With the switch in the 12V TRIG. position, the amplifier is turned on automatically when a 12 volt trigger signal is applied to the 3.5mm jack to the left of the switch. The amplifier will go into standby mode with no signal if the +12 volt signal is not present. The front panel POWER SWITCH must be ON for the +12V trigger to work. Turning the switch OFF cuts power to the amplifier, regardless of whether or not a trigger signal is present.

12V Trigger Input and Output 7

The jack labeled IN is for connecting the 3.5mm Plug/Cable carrying a +12 volt trigger signal to turn the amplifier on and off. To use

this feature the front panel Power Switch 1 must be set to the ON position. This input accepts any control signal (AC or DC) ranging from 3 volts to 30 volts.

The jack labeled OUT is for connecting another 3.5mm plug/cable to provide a 12V trigger signal to other components. The 12V output signal is available whenever a +12 volt trigger signal is applied to the IN connector.

Input Signal Connections 56

See Figure 2

The RB-1510 has conventional RCA type input connectors, the type found on nearly all audio equipment.

Note: To prevent loud potentially damaging noises, make sure the amplifier is turned off when you make any changes to the input signal configuration.

Select high quality audio interconnect cables. Connect each of the outputs from the preamplifier or signal processor to the corresponding input of the RB-1510 5.

Auto Turn On/Off Mode Selector 8

The amplifier provides three options for manual or automatic power on/off operation. These modes are selectable using a switch on the back panel.

With the switch in the OFF position, the amplifier is turned on or off manually using the front panel power switch. Use this mode if you are using a switched AC outlet to control power to the amplifier.

With the switch in the SIGNAL SENSING position, the amplifier turns on automatically when a signal is sensed at the inputs. The amplifier will go into standby mode with no signal. The front panel power switch must be ON for the signal sensing to work. Turning the switch OFF cuts power to the amplifier, regardless of whether or not a signal is present.

Input Mono Switch 4

In certain custom configurations you may want both channels of the RB-1510 to output the same signal. In such systems set the Input Mono switch to “On”. Use the Left channel input. That input signal will be output from both channels.

Front Panel Level Controls 3

The Level controls on the front panel let you control the output volume of the RB-1510. In most systems these controls should be turned up all the way (full clockwise position). In some situations, such as when the amplifier is part of a multi-room or bi-amplified speaker system, it may be necessary to reduce the output level. Turn the controls down (counterclockwise) as needed.

Turning down the level does not reduce the maximum output of the amplifier. It simply increases the input signal required to achieve maximum output power.

Image 8
Contents RB-1510 Do not use this unit near water Use only accessories specified by the manufacturerPower supply cord or plug has been damaged RB-1510 Stereo Power Amplifier Preamplifier Important Notes Remarques importantesWichtige Hinweise Notas ImportantesAbout Rotel ContentsWord About Watts AC Power and Control Getting StartedInput Signal Connections Speaker Connections Troubleshooting Front Panel Power Indicator Is Not LitProtection Indicator Is Lit SpecificationsRemarques importantes concernant la sécurité ’appareil est tombé, ou le coffret est endommagéSommaire Au sujet de RotelInstallation Pour démarrerCâbles Prise d’alimentation secteurSélecteur de mode Trigger 12 V Indicateur de protection LEDEntrée et sortie Trigger 12 volts Sélecteur d’entrée MonoPolarité et mise en phase Prises « de renvoi » modulationChoix des enceintes Choix de la section du câble d’enceintes’indicateur Power de mise sous tension ne s’allume pas Problèmes de fonctionnementSpécifications Pas de sonBenutzen Sie nur vom Hersteller empfohlenes Zubehör Das Netzkabel oder der Stecker beschädigt sindDas Gerät Regen ausgesetzt war Das Gerät hingefallen ist bzw. beschädigt wurdeInhaltsverzeichnis Die Firma RotelZu dieser Anleitung Netzspannung und BedienungEingangssignalanschlüsse Anschließen der Lautsprecher Bei Störungen Technische DatenDie Betriebsanzeige leuchtet nicht Kein TonInformación Importante Relacionada con la Seguridad El aparato ha sido golpeado o dañado de algún modoContenido Acerca de RotelAlgunas Precauciones Fabricación sean lo más limpios y ecológicos posiblePara Empezar Alimentación y ControlAlgunas Precauciones ColocaciónEntrada y Salida para Señal de Disparo de +12 V Indicador Luminoso de ProtecciónSelector del Modo de Conexión/Desconexión Conexión de las Cajas Acústicas Inhoud Wij van RotelDe luidsprekerkeuze De luidsprekerkabelkeuze Alles in faseAan de slag met de RB-1510 Een plek voor de RB-1510Hoe met de kabels om te gaan De lichtnetaansluitingDe Signaalverbindingen De Luidsprekeraansluitingen Wat te doen bij problemen? De lichtnetindicator werkt nietDe beveiligingsindicator licht op Technische gegevensUtilizzate esclusivamente accessori indicati dal produttore Importanti informazioni di SicurezzaAlcune Parole Sulla Rotel IndiceAlcune informazioni sui Watt Per Cominciare Alimentazione AC e comandiInterruttore di accensione e LED indicatore Indicatore di protezioneIngresso ed uscita +12V Trigger Commutatore Input MonoCollegamento dei diffusori Risoluzione dei problemi Il LED indicatore Protection è accesoCaratteristiche tecniche Nessun suonoViktiga säkerhetsinstruktioner Nätkabeln eller kontakten har skadatsOm Rotel Innehåll45 Några ord om watt Introduktion Ström och strömfunktionerAnslutningar för insignaler Högtalaranslutningar Felsökning SpecifikationerFrontens strömindikator lyser inte Inget ljud hörsПрибор побывал под дождем Важные инструкции по безопасностиСетевой шнур или штекер был поврежден Содержание Компании RotelПервые шаги Меры предосторожностиРазмещение КабелиВыключатель питания и индикатор питания Светодиодный индикатор защитыВход и выход для +12 В триггерного сигнала Переключатель входов в режим моно Input MonoВыбор акустических систем Выбор колоночного кабеляПолярность и фаза Подсоединение колоночных проводовДиагностика и устранение неисправностей Технические характеристикиНе светится индикатор питания на передней панели Нет звукаPhone +1 Fax +1 Shinsen-Cho Shibuya-Ku Tokyo JapanConcord Street North Reading, MA