1. Manuals
  2. Brands
  3. Home Audio
  4. Soundbar/SoundTower
  5. Samsung
  6. Home Audio
  7. Soundbar/SoundTower

Samsung SHR-6040P, SHR-6042P Event monitoring, Spot-outmonitoring, Zoom function, live _19, The smallest number Channel from in the event occurs Channel is print as Spot

1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 96
Download on canonical page 96 pages, 0 b

Zoom function

The Zoom function doubles the size of the selected area but it is active only in the full screen mode.

The zoom setup area appears when the ZOOM button is pressed in the full screen mode. You can adjust the location of the zoom setup area by using the Direction () buttons. If you press the Enter() button after selecting a setup area, the selected area is shown twice as big as the previous size. The image location can be adjusted by using the Direction () buttons even after enlarging the size. If the Enter() button is pressed again under the enlarged state, it will return to the zoom setup area and you can perform the Zoom Off function by using the ZOOM button.

Event monitoring

The event monitoring function displays the channel linked to the event when a specific event (sensor/motion) occurs. The event monitoring On/Off and event Duration functions can be set by using the command “MENUMonitoringLive Mode”.

When the event monitoring time has been set to 30 seconds, for example, the channel-2 appears for 30 seconds in the full screen mode if an event initially occurs in the channel-2 as shown in the figure below. If another event occurs within 30 seconds, it is also displayed together with the existing event.

When events occur from the channels 1 and 3 within 30 seconds after an event has occurred in the channel 2 (as shown in the figure). Then, the channels 1, 2 and 3 are switched to the full screen.

If no new event occurs within the event display duration, it will return to the previous live mode. If you press the ALARM button before the event display time exceeds, the event monitoring stops. If an event occurs, the ALARM LED lights and the ALARM LED is turned off if you press the ALARM button while the LED lights.

The alarm setting is initialized when the ALARM button is pressed. In this case, the Event icon disappears. The monitoring function can be cancelled while in event monitoring. The event recording with pre-event time and post-event time resumes after a new alarm occur.

Spot-out monitoring

The Spot-out monitoring is the function that monitors the entire screen of a specific channel with the output different from the live screen output. If a monitoring item is selected from the menu screen, you can select a specific channel as the Spot-out channel among the channels 1 to 4 and you can also monitor all the channels at an interval of auto sequence time. The live screen icons do not appear for Spot-out monitoring.

At this time, the auto sequence time internal is identical to the auto sequence time of the Spot mode.

The smallest number Channel from in the event occurs Channel is print as Spot.

live 04

Event Monitor Start

 

25 sec

55 sec

CAM_01 Event

CAM_03 Event

Event Monitoring Stop

live _19
MENU

Models