Panasonic KX-TDA100 manuals
Kitchen Appliance > Oven
When we buy new device such as Panasonic KX-TDA100 we often through away most of the documentation but the warranty.
Very often issues with Panasonic KX-TDA100 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Oven Panasonic KX-TDA100 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Oven on our side using links below.
Panasonic KX-TDA100 Installation Manual
282 pages 5.69 Mb
248 pages 5.75 Mb
2 System Components5 Important Safety Instructions7 Precaution11 IntroductionThe Structure of this Manual About the Other Manuals About the software version of your Hybrid IP-PBX Trademarks 12 Precautions for Users in the United KingdomFOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY. WARNINGTHIS APPLIANCE MUST BE EARTHED. 14 Table of Contents18 1.1 System Highlights1.1.1 System HighlightsNetworking Features Built-in Small Call Centre Features Computer Telephony Integration (CTI) Features Voice Mail Features Parallelled Telephone Features 19 Portable Station (PS) FeaturesPC Phone/PC Console Features Hospitality Features 20 1.2 Basic System Construction23 1.3 Optional Equipment26 1.4 Specifications38 2.1 Before Installation2.1.1 Before InstallationSafety Installation Instructions Installation Precautions Wiring Precautions 40 2.2 Installation of the Hybrid IP-PBX71 2.3 Information about the Main Processing Card75 2.4 Information about the Trunk Cards107 2.5 Information about the Extension Cards123 2.6 Information about the Other Cards136 2.7 Connection of Extensions145 2.8 Connection of DECT Portable Stations2.8.1 OverviewCS: Cell Station (KX-TDA0142CE/KX-TDA0141CE) PS: DECT Portable Station (KX-TCA155/KX-TCA255/KX-TD7590/KX-TD7580) RF Specification 147 2.8.2 Procedure Overview1. Investigate the installation site 2. Prepare for site survey 3. Conduct the site survey 148 4. Finish the site survey5. Connect the CS and PS to the Hybrid IP-PBX and test the operation 6. Mount the CS on the wall 149 2.8.3 Site PlanningUnderstanding Radio Waves1. Reflection 2. Diffraction 3. PenetrationCharacteristics of Radio Waves 1. 2. 3. Relationships Between Radio Waves and Building Structure and Materials CS Column 151 CS Coverage AreaSite Survey Preparation1. a. b. c. d. 2. a. b. C 153 2.8.4 Before Site SurveyChecking the CS ID Number Assigning the CS ID Number to the PS2.8 Connection of DECT Portable Stations 154 CS No. CS ID No.3 0 to 7 To clear the CS ID number assigned to the PS, follow the procedure below: A: C: E: B: D: F:# To clear one by one To clear all at once 2.8 Connection of DECT Portable S tations 155 Setting and Installing the CS Temporarily for Site Survey1. 2. If more than 1 CS is in Radio Signal Test mode, each CS must have a unique channel number. Channel Number Switch Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 DIP Switch 1 2 3 4 5 6 OFF ONRadio Signal Test Switch Channel 0 156 3. 4. 157 2.8.5 Site Survey Using the KX-TCA255/KX-TD7590Testing the Radio Signal StrengthLog No. Channel No.Log No. 2. 1. 158 a. b. c. 2.8 Connection of DECT Portable Stations 160 Referring to the Stored Scan DataPrevious or Next 0 to 9 Log No. Clearing the Stored Scan DataTo go to other slots To go to specific channel 161 2.8.6 After Site Survey162 2.8.7 Connecting a Cell Station to the Hybrid IP-PBXUsing a CSIF Card 163 Using a DHLC/DLC Card164 Connecting the CSRegistering the PSEntering the Hybrid IP-PBX System Programming Mode Using a PT PS Registration# System Password for Administrator for PT Programming Programming No. 166 [690]Extn. No.Setting the Personal Identification Number (PIN) for PS Registration Changing the Display Language of the PS 168 [692]2.8 Connection of DECT Portable S tations PS Termination / System Lock Password Handset PINUsing the KX-TD7580 If the registration information is still stored in the PS Using the KX-TCA155/KX-TCA255 169 [691]Select "Setting Handset". Select "Registration". Press POWER for 2 seconds. Select "YES". F / / / Handset PIN / 171 2.8.8 Wall Mounting173 2.9 Connection of 2.4 GHz Portable Stations2.9.1 OverviewCS: Cell Station (KX-TDA0142/KX-TDA0141) PS: 2.4 GHz Portable Station (KX-TD7680/KX-TD7690) 175 2.9.2 Procedure Overview1. Investigate the installation site 2. Prepare the CS for site survey 3. Conduct the site survey 176 4. Finish the site survey5. Connect the CS and PS to the Hybrid IP-PBX and test the operation 6. Mount the CS on the wall 177 2.9.3 Site PlanningUnderstanding Radio Waves1. Reflection 2. Diffraction 3. PenetrationCharacteristics of Radio Waves 1. 2. 3. Relationships Between Radio Waves and Building Structure and Materials CS Column 179 CS Coverage AreaSite Survey Preparation1. a. b. c. d. 2. a. b. C 181 2.9.4 Before Site SurveySetting and Installing the CS Temporarily for Site SurveyIf more than 1 CS is in Radio Signal Test mode, each CS must have a unique CS number. 1. 2. CS Number Switch CS no. 1 CS no. 2 CS no. 3 CS no. 4 CS no. 5 CS no. 6 CS no. 7 CS no. 8 CS no. 9 DIP Switch 1 2 3 4 5 6 OFF ONRadio Signal Test Switch 182 3. 4. 183 2.9.5 Site Survey187 2.9.6 After Site Survey188 2.9.7 Connecting a Cell Station to the Hybrid IP-PBX192 [690]Extn. No.F2 F3Choose "SYSTEM 14". Select "REGISTRATION". Choose "SYSTEM 14". Select "REGISTRATION". SEL SEL Setting the System LockWhen a system lock has been set, the system lock password will be required for PS system sett ing. 193 System Lock Password System Lock PasswordSEL ENTR CHNG SEL ENTR System Lock Password System Lock Password Setting the Personal Identification Number (PIN) for PS Registration 194 [692]PS Termination Testing the Operation 195 [691]198 2.10 Connection of Doorphones, Door Openers, External Sensors, and External Relays2.10.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays1. Maximum Cabling Distance Installing the Doorphone (KX-T30865) 199 Connection 201 2.11 Connection of Peripherals2.11.1 Connection of Peripherals 205 2.12 Power Failure Connections2.12.1 Power Failure Connections 209 2.13 Starting the Hybrid IP-PBX2.13.1 Starting the Hybrid IP-PBX 212 3.1 Overview213 3.2 Connection215 3.3 Installation of the KX-TDA Maintenance Console3.3.1 Installing and Starting the KX-TDA Maintenance ConsoleSystem Requirements Password SecurityWarning to the Administrator or Installer regarding the system password 1. 2. 3. 4. 5. 6. 216 Installing the KX-TDA Maintenance ConsoleStarting the KX-TDA Maintenance Console and Assigning the Basic Items (Quick Setup) 220 4.1 Troubleshooting240 5.1 Revision History
194 pages 4.5 Mb
Also you can find more Panasonic manuals or manuals for other Kitchen Appliance.