3Com 155 PCI What to Do If a Test Fails, Make sure the board is seated correctly in the slot

Models: 155 PCI

1 130
Download 130 pages 21.07 Kb
Page 102
Image 102
What to Do If a Test Fails

6-14 CHAPTER 6: DIAGNOSTICS AND TROUBLESHOOTING

SRAM Data Test : Passed

Total Repetitions Completed : 10

Repetitions Passed : 10

Repetitions Failed : 0

Internal Loopback Test : Passed

Total Repetitions Completed : 10

Repetitions Passed : 10

Repetitions Failed : 0

Interrupt Test : Passed

Total Repetitions Completed : 10

Repetitions Passed : 10

Repetitions Failed : 0

External Looopback Test Results

External Loopback Test : Passed

Total Repetitions Completed : 10

Repetitions Passed : 10

Repetitions Failed : 0

Halt On Error : YES

Test Repetitions : 10

NIC Maintained Statistics (if any):

---------------------------------------

Cells transmitted: 3760 Cells received:3760

Cells received with CRC error: 0

Cells received with Congestion Flag: 0

Cells received with Cell Loss Priority Flag: 0

Cells Drop error: 0

Invalid Cells error: 0

Diagnostic tests ended at: 12/09/96, 12:09:52

Figure 6-9 Sample of Diagnostic Test Report File

What to Do If a Test Fails

If the diagnostic tests fail, the 3C975 ATMLink NIC may not be defective. Follow these steps to test the NIC further.

CAUTION: Make sure to turn the power off and disconnect all cables from the NIC before inserting or removing it from the computer.

1Check the NIC installation by reviewing the installation instructions in Chapter 2.

Make sure the board is seated correctly in the slot.

Page 102
Image 102
3Com 155 PCI manual What to Do If a Test Fails, Make sure the board is seated correctly in the slot