SIC-1SAE 23

Straight-through cable: the wire sequences of the twisted pair cable crimped in the RJ-45 connectors at both ends are completely the same. It is used to connect terminal devices (such as PCs, routers) to Hubs or LAN Switches.

Crossover cable: The wire sequences of twisted pair cable crimped in the RJ-45 connectors at both ends are different. It can be used to connect two terminal devices (such as PCs and Routers). You can such kind of cables by yourself if necessary.

For the pinouts, identification and making methods of these two kinds of network cables, see Low-End and Mid-Range Series Routers Cable Manual.

Connecting the Interface If the SIC has been properly installed, follow these steps to connect the interface Cable cable:

Step 1: Connect the Ethernet port of SIC to a PC or router using a crossover cable and to a Hub or LAN Switch using a straight-through cable;

Step 2: Check the status of LINK LED on the SIC-1FEA panel: ON means the link is connected and OFF means the link is not connected. In the latter case, check the line.

SIC-1SAE

Introduction SIC-1SAE, 1-port enhanced high-speed synchronous/asynchronous serial interface card, provides functions similar to SA, but its serial interfaces support more protocols, such as RS449, X.21, and RS530.

Interface Attributes The interface attributes of the SIC-1SAE are given in the following table:

Table 3 Interface attributes of the SIC-1SAE

 

Description

 

 

Attribute

Synchronous

 

Asynchronous

 

 

 

 

Connector

DB-28

 

 

 

 

 

 

Number of connectors

1

 

 

 

 

 

 

Interface standard and

V.24

V.35, RS449,

RS232

operating mode

 

X.21, RS530

 

 

 

 

 

 

DTE, DCE

DTE, DCE

 

 

 

 

 

Minimum baud rate

1200

1200

300

(bps)

 

 

 

 

 

 

 

Maximum baud rate

64 k

2.048 M

115.2

(bps)

 

 

 

Page 23
Image 23
3Com MSR 50, MSR 30 Interface attributes of the SIC-1SAE, Description Attribute Synchronous Asynchronous, Dte, Dce