100CHAPTER 3: MULTIFUNCTIONAL INTERFACE MODULES

Table 59 Description of the LEDs on the MIM-1CT3 panel

LED

Description

 

 

LINK/ACT

ON means the carrier signal has been

 

received.

 

OFF means no carrier signal has been

 

received.

 

Blinking means data is being

 

transmitted or/and received.

 

 

LP/AL

ON means the interface is in a

 

loopback.

 

Blinking means an AIS, LFA, or RAI

 

alarm signal is present.

 

OFF means no loopback or alarm is

 

present.

 

 

Note:

 

AIS = Alarm indication signal; LFA = loss of frame alignment; RAI = Remote alarm indication

Interface Cable MIM-1CT3 and MIM-1CE3 use the same type of interface cables and make connection in the same way. For details, see “MIM-1CE3 Module” on page 97.

n E3/T3 cables are not provided together with MIM-1CT3 and shall be prepared by the user.

MIM-4BSE Module

Introduction MIM-4BSE, the four-port ISDN BRI interface module, transmits, receives, and processes four channels of ISDN BRI S/T data traffic on ISDN BRI S/T interfaces.

The MIM-4BSE differs from the 4BS only in the way they set matched resistance for an ISDN BRI S/T interface: the 4BS uses jumpers while the MIM-4BSE uses DIP switches.

The MIM-4BSE can work in dial mode or leased line mode.

Interface Attributes The following table describes the interface attributes of the MIM-4BSE.

Table 60 Interface attributes of the MIM-4BSE

Attribute

Description

 

 

Connector

RJ-45

Number of connectors

4

Cable

ISDN S/T cable

Protocol & standard

ITU-T I.430, Q.921, Q.931

Operating mode

ISDN dial-up

 

ISDN leased line