MIM-2VE1 Module 117

Table 77 Description of the LEDs on the MIM-HNDE panel

 

 

LED

Indication

 

 

STATUS

ON (green): The MIM-HNDE module is

 

powered on properly.

 

OFF: There is no power supply, damaged

 

power supply, or sever hardware failure.

ACTIVE

OFF after flashing yellow for two seconds:

 

Initialized the MIM-HNDE module.

Blinking continuously: The MIM-HNDE module operates normally and there is data transmission with the host.

OFF: MIM-HNDE module runs normally and no data transmission exists with the host.

Troubleshooting

1Symptom 1: The STATUS LED stays off after turning on the router.

Troubleshooting: The STATUS LED should stay solid on after powered on. The OFF status indicates that the MIM-HNDE module or some hardware is not powered on properly. Check the connection of the power supply.

If the device is powered on, the failure may due to the damaged power supply of the module, or abnormal operation of CPLD (Complex Programmable Logic Device). In these circumstances, contact our agents for support.

2Symptom 2: The ACTIVE LED stays off when powering on the router.

Troubleshooting: When powering up the device, the ACTIVE LED should flashing for two seconds before turning off, which indicates the encryption processor of the MIM-HNDE module has been configured and is ready for work. If the ACTIVE LED stays on when powering up the device, this means the initialization of the processor fails and the system bus does not work normally. Check the connection between the MIM-HNDE module and the host. If the connection is good, the abnormal status may due to the host or the MIM-HNDE module, contact our agents for support.

3Symptom 3: The ACTIVE LED stays on or off when the MIM-HNDE module is running.

Troubleshooting: The ACTIVE LED should be blinking when the MIM-HNDE module runs the encryption service. The solid on or off indicates the system bus works abnormally. Check the connection between the MIM-HNDE module and host. If the connection is good, the abnormal status may due to the host or the MIM-HNDE module, contact our agents for support.

MIM-2VE1 Module

Introduction 2-port E1 voice interface module (MIM-2VE1) can handle dense voice signals in VoIP system. It provides two CE1/PRI/R2 ports, allowing the access of 60 channels of voice signals.

Page 117
Image 117
3Com MSR 30, MSR 20, MSR 50 manual MIM-2VE1 Module, Troubleshooting