90CHAPTER 3: MULTIFUNCTIONAL INTERFACE MODULES

Figure 99 MIM-8E1 (120-ohm) panel

Figure 100 MIM-8E1 (75-ohm) panel

The following table describes the LEDs on the MIM-8E1/MIM-8E1-F panel:

Table 51 Description of the LEDs on the MIM-8E1/MIM-8E1-F panel

LED

Description

 

 

LINK

OFF means no link is present; ON

 

means a link is present.

ACTIVE

OFF means no data is being

 

transmitted or received. ON means

 

data is being transmitted or received.

 

 

Interface Cable The MIM-8E1/MIM-8E1-F module provides eight E1 ports and adopts a 120-ohm or a 75-ohm 8E1 conversion cable. The two types of cables look similar. Both of them have a DB-68 connector at one end for connecting the router. At the other end, however, the 75-ohm 8E1 conversion cable provides 16 coaxial cable connectors; and the 120-ohm 8E1 conversion cable provides eight twisted pair cable connectors, as shown in the following figures:

Figure 101 75-ohm 8E1 conversion cable

Page 90
Image 90
3Com MSR 30, MSR 20, MSR 50 manual MIM-8E1 120-ohm panel, Description of the LEDs on the MIM-8E1/MIM-8E1-F panel