SIC-1TPRI/SIC-1T1-F 35

Table 9 Description of the LEDs on SIC-1TPRI/SIC-1T1-F panel

 

 

LED

Description

 

 

LINK/ACT

ON means the carrier signal has been

 

received.

 

OFF means no carrier signal has been

 

received.

 

Blinking means data is being transmitted

 

or/and received.

LP/AL

ON means the interface is in a loopback.

 

Blinking means an AIS, LFA, or RAI alarm

 

signal is present.

OFF means no loopback or alarm is present.

Note:

AIS = Alarm indication signal; LFA = loss of frame alignment; RAI = Remote alarm indication

Interface Cable SIC-1TPRI/SIC-1T1-F interface cable is 100-ohm standard shielded network cable that has RJ-45 connectors at both ends. The following figure illustrates a SIC-1TPRI/SIC-1T1-F interface cable:

Figure 27 T1 cable

 

For the pinouts of T1 cable, see Low-End and Mid-Range Series Routers Cable

 

Manual.

c

CAUTION: Relevant cables are included in the standard shipment package of

SIC-1TPRI/SIC-1T1-F. Please order them together with SIC-1TPRI/SIC-1T1-F. By

 

default, they are not supplied.

Connecting the Interface Cable

c

CAUTION:

You should connect a cable to the port with the correct mark. Improper plugging is prone to impair the SIC/MIM and even damage the router.

When using T1 cable outdoors, you are recommended to install a special lightning arrester on the input end of the cable so as to avoid lightning more effectively.

If the SIC has been properly installed, follow these steps to connect the cable:

Step 1: Connect one end of the T1 cable to the RJ-45 port of SIC-1TPRI/SIC-1T1-F;

Page 35
Image 35
3Com MSR 50, MSR 30, MSR 20 manual Default, they are not supplied, Description of the LEDs on SIC-1TPRI/SIC-1T1-F panel