SIC-1FEF 61

and the other end into the BSV interface of the SIC-1BSV/SIC-2BSV interface card.

If the line is an ISDN S/T interface line, directly connect the cable to the BSV interface of the SIC-1BSV/SIC-2BSV interface card.

2To connect the interface card to a TE device, use a crossover S/T interface cable. Connect the RJ-45 plug at one end of the cable to the BSV interface, the RJ-45 receptacle to a straight-through S/T interface cable, and then the straight-through cable to the TE device.

SIC-1FEF

Introduction SIC-1FEF is short for 1-port 100 Mbps fiber Ethernet interface card, where FE is short for Fast Ethernet and F for fiber, indicating an optical fiber interface. SIC-1FEF is used for the communication between the router and LAN.

SIC-1FEF supports:

Five types of SFP removable optical interface modules: multimode short-haul (850 nm), single-mode medium-haul (1310 nm), single-mode long-haul (1310 nm), single-mode long-haul (1550 nm), and single-mode ultra-long haul (1550 nm).

1000 Mbps interface rate

Full duplex

Interface Attributes The following table describes the interface attributes of the SIC-1FEF.

Table 33 Interface attributes of SIC-1BSV/SIC-2BSV

Attribute

Description

 

 

 

 

 

 

 

 

 

 

 

Number of

1

 

 

 

 

connectors

 

 

 

 

 

 

 

 

 

 

 

 

Connector

SFP/LC

 

 

 

 

 

 

 

 

 

 

Interface standard

802.3, 802.3u, and 802.3ab

 

 

 

 

 

 

 

 

 

 

Transmitt Type

Multimode

Single-mode

Long-haul

Long-haul

Ultra-long

ing

short-haul

medium-ha

(1310 nm)

(1550 nm)

haul (1550

optical

(850 nm)

ul (1310

nm)

 

 

power

Optical

nm)

Optical

Optical

Optical

 

 

 

interface

interface

 

 

interface

Optical

interface

 

 

module

module

 

 

module

interface

module

 

 

 

 

 

 

 

module

 

 

 

 

 

 

 

 

 

 

 

Min.

-9.5 dBm

-9 dBm

-2 dBm

-4 dBm

-4 dBm

 

 

 

 

 

 

 

 

Max.

0 dBm

-3 dBm

5 dBm

1 dBm

2 dBm

 

 

 

 

 

 

Receiver sensitivity

-17 dBm

-20 dBm

-23 dBm

-21 dBm

-22 dBm

 

 

 

 

 

 

Central

850 nm

1310 nm

1310 nm

1550 nm

1550 nm

wavelength

 

 

 

 

 

 

 

 

 

 

 

Fiber type

62.5/125

9/125 μm

9/125 μm

9/125μm

9/125μm

 

 

μm

single mode

single mode

single mode

single mode

 

 

multimode

 

 

 

 

 

 

 

 

 

 

Max. transmission

0.55 km

10 km (6.21

40 km (24.86

40 km (24.86

70 km (43.50

segment

(0.34 mi.)

mi.)

mi.)

mi.)

mi.)