FIC-1E1/FIC-2E1/FIC-4E1 and FIC-1E1-F/FIC-2E1-F/FIC-4E1-F 167

Figure 204 Default setting of the DIP switches for the FIC-E1/FIC-E1-F cards

on

1

2

3

4

5

6

7

8

The following table describes how to set a DIP switch on the FIC-E1/FIC-E1-F cards:

Table 115 Setting DIP switches on the FIC-E1/FIC-E1-F cards

 

 

 

Configuration of

 

 

Configuration of

120-ohm

DIP switch

Description

75-ohm impedance

impedance

 

 

 

 

1BIT

75-ohm/120-ohm

ON

OFF

 

toggle switch

 

 

2BIT

ON

OFF

 

 

 

 

 

3BIT

 

ON

OFF

 

 

 

 

4BIT

 

ON

OFF

 

 

 

 

5BIT

 

ON

OFF

 

 

 

 

6BIT

RxRing grounding

OFF: RxRing is

-

 

mode switch

grounded using

 

 

 

capacitance.

 

 

 

ON: RxRing is

 

 

 

grounded directly.

 

 

 

 

 

7BIT

RxShield grounding

-

ON: RxShield is

 

switch

 

grounded.

 

 

 

OFF: RxShield is not

 

 

 

grounded.

 

 

 

 

8BIT

RxShield grounding

-

OFF: RxShield is

 

mode switch

 

grounded using

 

 

 

capacitance

 

 

 

ON: RxShield is

 

 

 

grounded directly.

 

 

 

 

c CAUTION: When connecting an FIC-E1/FIC-E1-F card to an external 75-ohm cable, you are recommended to place BITs 1 through 8 to the ON position; when connecting the card to an external 120-ohm cable, place BITs 1 through 8 to the OFF position. Only trained personnel are allowed to change the settings of the DIP switches.

By default, all the DIP switch BITs are in the ON position (factory default), which means the impedance of E1 ports is 75-ohm.

Page 167