32CHAPTER 2: SMART INTERFACE CARDS

If the SIC has been properly installed, follow these steps to connect the cable:

Step 1: Check the type of E1 cable and correctly set the DIP switch (the ex-factory setting of E1/CE1/PRI interface impedance is 75-ohm);

Step 2: Connect the DB-15 connector of E1 cable to SIC-1EPRI/SIC-1E1-F;

Step 3: Connect the other end of the E1 cable to the corresponding network device:

1When the E1 cable is a 75-ohm unbalanced coaxial cable:

Directly connect the BNC connector of the cable to the remote equipment if there is no need for extension, or

Connect the BNC connector of the cable to the coaxial connector and the other end of the coaxial connector to the remote network equipment through a 75-ohm E1 trunk cable, if cable extension is needed.

CAUTION: The wire marked TX in the E1 cable should be connected to the peer

c wire marked RX and the wire marked RX should be connected to the peer wire

marked TX.

 

 

 

 

 

Figure 23 Extending an E1 75-ohm non-balanced coaxial cable

 

 

 

 

DB -15

BNC

Network

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BNC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Router

 

 

 

 

 

 

 

 

 

 

 

 

 

 

devices

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

such as DDN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coaxial connector

75-ohm E1 trunk cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75-ohm non-balanced coaxial cable

 

 

 

 

 

If the remote device has 120-ohm interface, it is needed to use a 75-ohm-to-120-ohm adapter or use a 120-ohm cable.

2When the E1 cable is a 120-ohm balanced twisted pair cable:

Directly connect the RJ-45 connector of the cable to the RJ-45 port of the remote equipment, if there is no need to extend the E1 cable, or

Connect the RJ-45 connector of the cable to the network connector and the other end of the network connector to the network equipment through a 120-ohm E1 trunk cable, if cable extension is needed.