86CHAPTER 3: MULTIFUNCTIONAL INTERFACE MODULES

Figure 96 Default setting of DIP switches for MIM-1E1/MIM-2E1/MIM-4E1 and

MIM-1E1-F/MIM-2E1-F/MIM-4E1-F modules

on

1

2

3

4

5

6

7

8

Description of DIP switch settings is given in the following table for

MIM-1E1/MIM-2E1/MIM-4E1 and MIM-1E1-F/MIM-2E1-F/MIM-4E1-F modules:

Table 49 Description of DIP switch settings of MIM-1E1/MIM-2E1/MIM-4E1 and

MIM-1E1-F/MIM-2E1-F/MIM-4E1-F modules

 

 

Configuration of

Configuration of

DIP

Description

75-ohm impedance

120-ohm impedance

 

 

 

 

1BIT

75-ohm/120-ohm

ON

OFF

 

selection switch

 

 

2BIT

ON

OFF

 

 

 

 

 

3BIT

 

ON

OFF

 

 

 

 

4BIT

 

ON

OFF

 

 

 

 

5BIT

 

ON

OFF

 

 

 

 

6BIT

RxRing grounding

OFF: RxRing is

-

 

mode selection

grounded via

 

 

switch

capacitance.

 

 

 

ON: RxRing is

 

 

 

grounded directly.

 

 

 

 

 

7BIT

RxShield grounding

-

ON: RxShield is

 

mode selection

 

grounded.

 

switch

 

OFF: RxShield is not

 

 

 

 

 

 

grounded.

 

 

 

 

8BIT

SxShield grounding

-

OFF: RxShield is

 

mode selection

 

grounded via

 

switch

 

capacitance

 

 

 

ON: RxShield is

 

 

 

grounded directly.

 

 

 

 

c CAUTION:

It is recommended to select the DIP switch of MIM-1E1/MIM-2E1/MIM-4E1 and MIM-1E1-F/MIM-2E1-F/MIM-4E1-F modules in this way: when connecting

75-ohm cable, flip BIT1-8 to ON, and when connecting 120-ohm cable, flip BIT1-8 to OFF. Positions of DIP switches can only be changed by the trained personnel.

Page 86
Image 86
3Com MSR 50, MSR 30, MSR 20 manual Dip