Programming Commands

CALCulate2 Subsystem

When there is no input signal, the POWer query returns –200 dBm; the WAVelength query returns 100 nm (1.0E–7).

PEXCursion

Sets the peak excursion limit used by the Agilent 86120C to determine valid laser line peaks.

Syntax

:CALCulate2:PEXCursion{? {<integer> MINimum MAXimum DEFault}}

 

<integer> represents logarithmic units in dB. Valid range is 1 to 30 dB.

 

Constant

Description

 

MINimum

1 dB

 

MAXimum

30 dB

 

DEFault

15 dB

Attribute

Non- sequential command

Summary

Preset State: 15 dB

 

*RST State: 15 dB

 

SCPI Compliance: instrument specific

Description

A laser line is identified as a valid peak if its amplitude is greater

 

than the peak excursion plus the amplitudes of the closest local min-

 

ima on either side of the peak. This command works in conjunction

 

with the peak threshold setting. Refer to “PTHReshold” on page 4- 34.

 

Changing the peak excursion limit causes the instrument to reprocess

 

the current set of data. Refer also to “Defining Laser- Line Peaks” on

 

page 2- 15.

 

The query response is the current value. For example, if the current value is set to 15 dB, the following value is returned:

15

4-33

Page 161
Image 161
Agilent Technologies Agilent 86120C manual PEXCursion, Syntax, Attribute, Summary, Description

Agilent 86120C specifications

Agilent Technologies is renowned for its innovative solutions in the field of electronic measurement and test instrumentation. Among its extensive portfolio, the Agilent 86120C stands out as a high-performance optical sampling oscilloscope designed for advanced optical communication system testing and development.

One of the key features of the Agilent 86120C is its ability to perform high-speed digital modulation analysis. With a bandwidth of up to 20 GHz, it supports a wide range of optical signals, making it ideal for testing and characterizing various optical components and systems. The device is capable of analyzing multiple modulation formats, including pulse amplitude modulation (PAM-4), making it a critical tool for engineers working on next-generation data transport technologies.

Another outstanding characteristic of the Agilent 86120C is its sophisticated optical performance monitoring capabilities. It employs advanced algorithms and techniques to provide real-time assessment of signal integrity. The oscilloscope can measure parameters such as eye diagrams, jitter, and signal-to-noise ratios, which are crucial for ensuring the reliability and performance of optical communication links.

Incorporating cutting-edge technologies, the Agilent 86120C features a high-sensitivity photodetector optimized for low-light detection and high-speed applications. This allows users to accurately capture and analyze signals, even when working with low-power transmission systems. The oscilloscope also supports multiple input channels, enabling simultaneous testing of multiple wavelengths or different signal paths.

User-friendly software is another highlight of the Agilent 86120C. The intuitive interface streamlines the measurement process and provides comprehensive data analysis tools. Users can quickly generate reports, conduct statistical analysis, and visualize data in various formats to enhance their understanding of signal behavior.

Additionally, the Agilent 86120C is equipped with connectivity options for seamless integration into larger test setups. It can easily interface with other Agilent test instruments, PCs, and networked environments, allowing engineers to create a comprehensive testing environment tailored to their specific needs.

In conclusion, the Agilent 86120C optical sampling oscilloscope combines high performance, advanced features, and cutting-edge technologies to meet the demanding requirements of optical communication testing. Its versatility makes it an essential tool for engineers working in the rapidly evolving field of data communications.