TTLT pairs to SLAVe modules

 

 

 

 

MASTer MODE

SLAVe MODE

Sample line

Trigger line

 

 

 

 

MASTer0

SLAVe0

TTLT0

TTLT1

 

 

 

 

MASTer2

SLAVe2

TTLT2

TTLT3

 

 

 

 

MASTer4

SLAVe4

TTLT4

TTLT5

 

 

 

 

MASTer6

SLAVe6

TTLT6

TTLT7

 

 

 

 

Executable when initiated: YES

Coupled command: NO

Reset (*RST) condition: NORMal mode

TRIGger:MODE?

TRIGger:MODE? queries the trigger mode setting. Returns NORMal,

MASTer or SLAVe.

TRIGger:SLOPe[<n>]

TRIGger:SLOPe[<n>] POS 1 NEG 0 sets the active edge of the trigger signal that causes a measurement to be made.

Parameters

Comments

Name

Type

Range of Values

Default Value

 

 

 

 

<n>

numeric

1 or 2

none

 

 

 

 

Trigger Source Must be INTernal or EXTernal: Trigger slope is active only when the trigger source is one of the four INTernal levels (TRIG:SOURce INT1-4) or when the EXTernal trigger source is specified (TRIG:SOURce EXTernal).

Two Trigger Sources: There are two trigger sources and you must designate which source you are setting the slope. Use n = 1 for the slope of trigger source number 1 and n = 2 for the slope of trigger source number 2. Trigger slope defaults to n = 1 if <n> is not designated.

Executable when initiated: YES

Coupled command: TRIG:SOURce INT1-4 and TRIG:SOURce EXTernal

Reset (*RST) condition: SLOPe1 = POSitive and SLOPe2 = POSitive

106 Digitizers Command Reference

Chapter 3

Page 106
Image 106
Agilent Technologies E1564A TRIGgerMODE?, TRIGgerSLOPen, Ttlt pairs to SLAVe modules, Executable when initiated YES

E1563A, E1564A specifications

Agilent Technologies, a prominent player in the field of electronic measurement, offers a range of products designed for various testing applications. Among their notable offerings are the E1564A and E1563A modules. Both models are designed for high-performance testing and measurement, catering particularly to the needs of engineers and technicians in the telecommunications and wireless industries.

The Agilent E1564A is a high-speed data and synchronization generation module, specifically tailored for advanced signal analysis. One of its primary features is its ability to provide a wide range of modulation types, including QPSK and 16QAM, which are essential for testing modern communication systems. The module also boasts a flexible output that supports multiple channels, making it efficient for testing complex systems where multiple data streams are present. Its exceptional performance in generating accurate waveforms enables engineers to perform thorough tests and validations on their devices.

On the other hand, the E1563A module is predominantly focused on protocol analysis and provides engineers with insights into the behavior of their communication systems. This module features comprehensive support for various communication protocols, making it invaluable when debugging and validating designs. Engineers can utilize the extensive measurement capabilities of the E1563A to analyze data integrity and system performance, ensuring that their products meet required specifications.

Both modules leverage advanced technologies from Agilent, ensuring high accuracy and reliability in measurements. They are equipped with powerful processing capabilities that allow for real-time data analysis, a critical aspect when working with high-frequency signals. Furthermore, these modules are designed for seamless integration into Agilent’s test and measurement platforms, enhancing usability and facilitating complex testing scenarios.

In summary, the Agilent E1564A and E1563A modules represent cutting-edge solutions for engineers involved in testing and validating communication systems. With their robust features, including support for various modulation schemes and protocol analysis, these modules enable efficient and accurate measurements. The commitment to quality and precision from Agilent Technologies continues to make these devices essential tools in the industry, helping engineers push the boundaries of innovation in telecommunications.