E

E1563A gain adjustment, 166 E1564A gain adjustment, 167 error messages, 145

calibration errors, 149 execution errors, 145 self-test errors, 149

examples

Digitizer Self-Test,153 Initial Operation, 30

Master Module Configuration, 39 Sampling Using Immediate Triggering, 43 Slave Module Configuration, 40 Three-Wire Connections (Bridge), 25 Three-Wire Connections (Voltage Measure), 26 Triggering Using External Triggering, 44 Triggering Using Internal Level Trigger, 43 Two-Wire Connections (Coaxial Cable), 26 Two-Wire Connections (Differential Source), 27

F

FIFO High Word/Low Word registers, 128 Filter Bandwidth verification test, 157 format, common commands, 45 FORMat subsystem

FORMat[:DATA], 72

FORMat[:DATA]?, 72 front panel features, 14 functional verification test, 153

G

Gain Verification test, 156

I

ID register, 126 implied commands, 46 initial operation, 30 INITiate subsystem

INITiate:CONTinuous, 73

INITiate:CONTinuous?, 74 INITiate[:IMMediate], 74

input overload condition, 36 INPut subsystem

INPut:FILTer[:LPASs]:FREQ, 75 INPut:FILTer[:LPASs]:FREQ?, 75 INPut:FILTer[:LPASs][:STATe], 76 INPut:FILTer[:LPASs][:STATe]?, 76 INPut[:STATe], 76 INPut[:STATe]?, 76

installing digitizers in mainframe, 22 Interrupt Control register, 129 interrupt line, setting, 21 Interrupt Source register, 130

L

linking commands, 47 logical address, setting, 21

M

master-slave operation, 38 measurement uncertainty, 158

N

Noise Verification test, 155

O

Offset and Cache Count register, 128 offset, register, 123

operation, digitizers, 33 OUTPut subsystem

OUTPut:TLT:SOURce?, 77

OUTput:TTLT:SOURce, 77

OUTPut:TTLT[:STATe], 78

OUTPut:TTLT[:STATe]?, 78 overload voltages, 14

P

Performance Test Record, 158 performance tests, conditions, 152 performance verification

Filter Bandwidth test, 157 Gain Verification test, 156 Noise Verification test, 155

performance verification test programs, 152 performance verification tests, 154 power-on state, 35

Pre-Trigger Count High Word register, 136 Pre-Trigger Count Low Word register, 137 programming, register-based,121

R

RAM, adding, 19

Range, Filter, Connect Channel 1, 2 register, 133 Range, Filter, Connect Channel 3, 4 register, 133 READ registers, 125

recommended test equipment, 151 register descriptions, 124

Index 171

Page 171
Image 171
Agilent Technologies E1563A, E1564A user manual Index

E1563A, E1564A specifications

Agilent Technologies, a prominent player in the field of electronic measurement, offers a range of products designed for various testing applications. Among their notable offerings are the E1564A and E1563A modules. Both models are designed for high-performance testing and measurement, catering particularly to the needs of engineers and technicians in the telecommunications and wireless industries.

The Agilent E1564A is a high-speed data and synchronization generation module, specifically tailored for advanced signal analysis. One of its primary features is its ability to provide a wide range of modulation types, including QPSK and 16QAM, which are essential for testing modern communication systems. The module also boasts a flexible output that supports multiple channels, making it efficient for testing complex systems where multiple data streams are present. Its exceptional performance in generating accurate waveforms enables engineers to perform thorough tests and validations on their devices.

On the other hand, the E1563A module is predominantly focused on protocol analysis and provides engineers with insights into the behavior of their communication systems. This module features comprehensive support for various communication protocols, making it invaluable when debugging and validating designs. Engineers can utilize the extensive measurement capabilities of the E1563A to analyze data integrity and system performance, ensuring that their products meet required specifications.

Both modules leverage advanced technologies from Agilent, ensuring high accuracy and reliability in measurements. They are equipped with powerful processing capabilities that allow for real-time data analysis, a critical aspect when working with high-frequency signals. Furthermore, these modules are designed for seamless integration into Agilent’s test and measurement platforms, enhancing usability and facilitating complex testing scenarios.

In summary, the Agilent E1564A and E1563A modules represent cutting-edge solutions for engineers involved in testing and validating communication systems. With their robust features, including support for various modulation schemes and protocol analysis, these modules enable efficient and accurate measurements. The commitment to quality and precision from Agilent Technologies continues to make these devices essential tools in the industry, helping engineers push the boundaries of innovation in telecommunications.