*WRITE BITS (Status/Control Register)

 

 

 

bit 0

R

Writing a "1" to this bit resets the digitizer to the power-on state. You must set bit 0 back

 

 

to a logical "0" before resuming normal operations of the module.

 

 

 

bit 1

S

“1” inhibits sysfail, “0” does not inhibit sysfail.

 

 

 

bit 6

E

“1” disables error reporting LED, “0” enables error reporting LED (front panel).

 

 

 

bit 7

F

“1” disables Flash ROM “write”, “0” enables Flash ROM “write”.

 

 

 

bit 12

A24

“1” sets A24 space as all FIFO, “0” sets A24 space as broken up.

 

 

 

bit 13

MOT-INTEL

“1” sets Motorola format for reading ordering, “0” sets Intel format for reading ordering.

 

 

 

bit 15

A

“1” enables A32 decoding, “0” enables A24 decoding.

 

 

 

 

 

**READ BITS (Status/Control Register)

 

 

 

bit 0

R

Reset Status; "1" = module reset, "0" = normal operation.

 

 

 

bit 1

S

SYSFAIL inhibit; “1” = inhibited, “0” = not inhibited.

 

 

 

bit 2

P

Passed; “1” = passed, “0” = failed.

 

 

 

bit 3

RDY

Ready; “1” = A32 decoding enabled, “0” = A24 decoding enabled.

 

 

 

bits 4 & 5

Arm

Bit 4 is “1” for 1 msec after a range/filter change then returns to “0”, bit 5 is “1”

 

Delay

for 30 msec after range/filter change then returns to “0”.

 

 

 

bit 6

E

Error; “1” disables front panel error LED, “0” enables front panel error LED.

 

 

 

bit 7

F

Flash ROM; “1” disables Flash ROM “write”, “0” enables Flash ROM “write”.

 

 

 

bits 8, 9,

Memory

Memory Size; “000” = 4 MBytes, “001” = 8 MBytes, “010” = 16 MBytes, “011” = 32 MBytes,

and 10

Size

“100” = 64 MBytes, “101” = 128 MBytes.

 

 

 

bit 12

A24

“1” sets A24 space as all FIFO, “0” sets A24 space as broken up.

 

 

 

bit 13

MOT-

“1” = Motorola big endian byte swapping, “0” = Intel little endian byte swapping.

 

INTEL

 

 

 

 

bit 14

M

MODID bit; if the bit is "0", module has been selected.

 

 

 

bit 15

A

A24/A32 enable; “1” = A32 decoding enabled, “0” = A24 decoding enabled.

 

 

 

Reading the Register Via Command Module PEEK command: DIAG:PEEK? 2083332,16 (2083328 = base with logical address 40 + 04 offset - see Figure B-2)

Via Digitizer Module PEEK command: DIAG:PEEK? 2 (2 signifies the third word, 16 bits, zero-base numbering system)

Appendix B

Register-Based Programming 127

Page 127
Image 127
Agilent Technologies E1563A, E1564A user manual Write Bits Status/Control Register, Read Bits Status/Control Register

E1563A, E1564A specifications

Agilent Technologies, a prominent player in the field of electronic measurement, offers a range of products designed for various testing applications. Among their notable offerings are the E1564A and E1563A modules. Both models are designed for high-performance testing and measurement, catering particularly to the needs of engineers and technicians in the telecommunications and wireless industries.

The Agilent E1564A is a high-speed data and synchronization generation module, specifically tailored for advanced signal analysis. One of its primary features is its ability to provide a wide range of modulation types, including QPSK and 16QAM, which are essential for testing modern communication systems. The module also boasts a flexible output that supports multiple channels, making it efficient for testing complex systems where multiple data streams are present. Its exceptional performance in generating accurate waveforms enables engineers to perform thorough tests and validations on their devices.

On the other hand, the E1563A module is predominantly focused on protocol analysis and provides engineers with insights into the behavior of their communication systems. This module features comprehensive support for various communication protocols, making it invaluable when debugging and validating designs. Engineers can utilize the extensive measurement capabilities of the E1563A to analyze data integrity and system performance, ensuring that their products meet required specifications.

Both modules leverage advanced technologies from Agilent, ensuring high accuracy and reliability in measurements. They are equipped with powerful processing capabilities that allow for real-time data analysis, a critical aspect when working with high-frequency signals. Furthermore, these modules are designed for seamless integration into Agilent’s test and measurement platforms, enhancing usability and facilitating complex testing scenarios.

In summary, the Agilent E1564A and E1563A modules represent cutting-edge solutions for engineers involved in testing and validating communication systems. With their robust features, including support for various modulation schemes and protocol analysis, these modules enable efficient and accurate measurements. The commitment to quality and precision from Agilent Technologies continues to make these devices essential tools in the industry, helping engineers push the boundaries of innovation in telecommunications.