D (continued)

digitizers accuracy, 158 adding RAM, 19 addressing registers, 121 adjustment procedures, 164 adjustments, 163 application examples, 42 base address, 122

block diagram, 33

cable connector assembly, 27 cabling considerations, 23 calibration, 163

calibration bus output port, 24

Calibration Flash ROM Address register, 131 Calibration Flash ROM Data register, 132 calibration intervals, 163

Calibration Source register, 132 channel block diagram, 34 command types, 45 configuring, 19

CVTable Channel 1 register, 130 CVTable Channel 2 register, 130 CVTable Channel 3 register, 131 CVTable Channel 4 register, 131 description, 13

Device Type register, 126 E1563A front panel features, 15 E1563A gain adjustment, 166 E1564A front panel features, 16 E1564A gain adjustment, 167 error messages, 145 external trigger input port, 24 external triggering, 38

FIFO High Word/Low Word registers, 128 Filter Bandwidth verification test, 157 front panel features, 14

Gain Verification performance test, 156 ID register, 126

initial operation, 30 input cabling, 2-wire,24 input cabling, 3-wire,24 input model, 25

input overload, 36 installing in mainframe, 22 internal triggering, 37 Interrupt Control register, 129 Interrupt Source register, 130

digitizers (cont’d) master-slave operation, 38 measurement uncertainty, 158 memory sizes, 13

Noise Verification perfomance test, 155 Offset and Cache Count register, 128 operation, 33

overload voltages, 14 performance test conditions, 152 Performance Test Record, 158 power-on state, 35

Pre-Trigger Count High Word register, 136 Pre-Trigger Count Low Word register, 137 Range, Filter, Connect Channel 3, 4 register, 133 READ registers, 125

recommended test equipment, 151 register descriptions, 124 register offset, 123 register-based programming, 121 reset state, 35

Sample Control register, 138

Sample Count High Byte register, 137 Sample Count Low Word register, 137 Sample Period High Byte register, 136 Sample Period Low Word register, 136 Samples Taken High Byte register, 131 Samples Taken Low Word register, 131 SCPI commands, 45

setting interrupt line, 21 setting logical address, 21 specifications, 119 Status/Control register, 126 Test Accuracy Ratio, 158 trigger block diagram, 35 Trigger Control register, 137 trigger input port cables, 24 trigger sources, 37

Trigger/Interrupt Level Channel 1 register, 134 Trigger/Interrupt Level Channel 2 register, 135 Trigger/Interrupt Level Channel 3 register, 135 Trigger/Interrupt Level Channel 4 register, 136 triggering, 37

verification tests, 151 WRITE registers, 124

Zero Adjustment procedures, 165 Zero Offset verification test, 154

digitizers application examples, 42 documentation history, 10

170 Index

Page 170
Image 170
Agilent Technologies E1564A, E1563A user manual Index

E1563A, E1564A specifications

Agilent Technologies, a prominent player in the field of electronic measurement, offers a range of products designed for various testing applications. Among their notable offerings are the E1564A and E1563A modules. Both models are designed for high-performance testing and measurement, catering particularly to the needs of engineers and technicians in the telecommunications and wireless industries.

The Agilent E1564A is a high-speed data and synchronization generation module, specifically tailored for advanced signal analysis. One of its primary features is its ability to provide a wide range of modulation types, including QPSK and 16QAM, which are essential for testing modern communication systems. The module also boasts a flexible output that supports multiple channels, making it efficient for testing complex systems where multiple data streams are present. Its exceptional performance in generating accurate waveforms enables engineers to perform thorough tests and validations on their devices.

On the other hand, the E1563A module is predominantly focused on protocol analysis and provides engineers with insights into the behavior of their communication systems. This module features comprehensive support for various communication protocols, making it invaluable when debugging and validating designs. Engineers can utilize the extensive measurement capabilities of the E1563A to analyze data integrity and system performance, ensuring that their products meet required specifications.

Both modules leverage advanced technologies from Agilent, ensuring high accuracy and reliability in measurements. They are equipped with powerful processing capabilities that allow for real-time data analysis, a critical aspect when working with high-frequency signals. Furthermore, these modules are designed for seamless integration into Agilent’s test and measurement platforms, enhancing usability and facilitating complex testing scenarios.

In summary, the Agilent E1564A and E1563A modules represent cutting-edge solutions for engineers involved in testing and validating communication systems. With their robust features, including support for various modulation schemes and protocol analysis, these modules enable efficient and accurate measurements. The commitment to quality and precision from Agilent Technologies continues to make these devices essential tools in the industry, helping engineers push the boundaries of innovation in telecommunications.