4Low Frequency Multiplexer Switch Modules

34924A D-Connectors

Bank 1

 

 

 

 

 

 

Bank 1

 

Bank 2

 

 

 

 

 

 

 

 

 

 

 

For orientation, the D-sub connector end of the module is facing you.

 

 

 

 

 

 

 

 

COM COM

 

 

 

 

 

 

 

 

 

6H

6L

1H

1L

7H

7L

2H

2L

1H

1L

3H

3L

9H

9L

4H

4L

10H

10L

5H

5L

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

16H

16H

11L

11H

17H

17L

12H

12L

8H

8L

34H

34L

19H

19H

14H

14L

20H

20L

Interlock1

 

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

GND

26H

26L

21H

21L

22H

22L

27H

27L

13H

13L

28H

28L

24L

24L

29H

29L

15H

15L Interlock 1

40

41

52

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

GND

32H

32L

31H

31L

33H

33L

18H

18L

23H

23L

35H

35L

30H

30L

25H

25L

NC

NC

 

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

Pin

 

 

 

 

 

 

 

 

 

 

 

 

1H

3

8H

29

15H

57

22H

45

29H

55

COM1 H

9

 

 

 

 

 

 

 

 

 

 

 

 

1L

4

8L

30

15L

58

22L

46

29L

56

COM1 L

10

 

 

 

 

 

 

 

 

 

 

 

 

2H

7

9H

13

16H

21

23H

69

30H

73

Interlock 1

39

 

 

 

 

 

 

 

 

 

 

 

 

2L

8

9L

14

16L

22

23L

70

30L

74

Interlock 1

59

 

 

 

 

 

 

 

 

 

 

 

 

3H

11

10H

17

17H

25

24H

53

31H

63

GND

40

 

 

 

 

 

 

 

 

 

 

 

 

3L

12

10L

18

17L

26

24L

54

31L

64

GND

60

 

 

 

 

 

 

 

 

 

 

 

 

4H

15

11H

23

18H

67

25H

75

32H

61

No Connect

77

 

 

 

 

 

 

 

 

 

 

 

 

4L

16

11L

24

18L

68

25L

76

32L

62

No Connect

78

 

 

 

 

 

 

 

 

 

 

 

 

5H

19

12H

27

19H

33

26H

41

33H

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5L

20

12L

28

19L

34

26L

42

33L

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6H

1

13H

49

20H

37

27H

47

34H

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6L

2

13L

50

20L

38

27L

48

34L

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7H

5

14H

35

21H

43

28H

51

35H

71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7L

6

14L

36

21L

44

28L

52

35L

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

As a safety feature, interlock 1 pins (39 and 59) on Bank 1 must

be shorted to enable the Bank 1 Analog Bus relays to close. The

 

 

optional 34924T terminal block shorts these pins for you. This

 

feature protects inadvertent routing of high voltages from the

 

Analog Buses to the D-sub connector of the module.

 

 

124

34980A User’s Guide

Page 136
Image 136
Agilent Technologies Switch/Measure manual 34924A D-Connectors, Bank