Agilent Technologies Switch/Measure manual DAC Output, Configuring a Multifunction Module

Models: Switch/Measure

1 216
Download 216 pages 59.53 Kb
Page 212
Image 212

10Multifunction Module with DIO, D/A, and Totalizer

The following command configures totalizer channel 5 on the Multifunction module in slot 2 to be reset to "0" after it is read (RRESet means “read and reset”).

CONFigure:TOTalize RRES,(@2005)

Example: Configuring the totalizer for count This command configures the totalizer to count on the rising edge (positive) or falling edge (negative) of the input signal. The following command configures the totalizer (channel 5) on a Multifunction module in slot 3 to count on the negative edge (falling) of the input signal.

TOTalize:SLOPe NEGative,(@3005)

Example: Clearing count on the totalizer channel This command immediately clears the count on the specified totalizer channels. The following commandclears the count on the totalizer (channel 5) on a Multifunction module in slot 3.

TOTalize:CLEAR:IMMediate (@3005)

DAC Output

Example: Setting output voltage This command sets the output voltage level for the specified DAC channels. The following command outputs +2.5 V DC on DAC channels (6 and 7) of a Multifunction module in slot 4.

SOURce:VOLTage 2.5,(@4006,4007)

Configuring a Multifunction Module

Example: Querying the system for module identify

The following command

returns the identify of the module installed in slot 7.

SYSTem:CTYPe? 7

 

Example: Resetting module(s) to power-on state

The following command

resets a module in slot 4 to its power- on state. SYSTem:CPON 4

200

34980A User’s Guide

Page 212
Image 212