Low Frequency Multiplexer Switch Modules

4

34921A D-Sub Connectors

Bank 1

Bank 1

Bank 2

For orientation, the D-sub connector end of the module is facing you.

*TSIL represents Temperature Sensor Interface Line. This line is used for temperature interface only.

WARNING As a safety feature, interlock 1 pins (17 and 33) on Bank 1 must be shorted to enable the Bank 1 Analog Bus relays to close. The optional 34921T terminal block shorts these pins for you. This feature protects inadvertent routing of high voltages from the Analog Bus to the D-sub connector of the module.

 

 

 

 

 

 

 

COM COM

 

 

 

 

 

 

 

 

 

 

1H

1L

2H

2L

 

3H

3L

1H

1L

4H

4L

14H

14L

5H

5L

20H

20L Interlock1

1

2

3

4

 

5

6

7

8

9

10

11

 

12

13

14

15

 

16

17

TSIL* 11H

11L

7H

7L

17H

17L

13H

13L

9H

9L

19H

19L 15H

15L Interlock 1

18

 

19

20

21

22

 

23

24

25

26

27

28

29

 

30

31

32

 

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMP AMP AMP AMP

GND

6H

6L

16H

16L 12H

12L

8H 8L

18H

18L

10H

10L 41L

41I

 

42L

42I

34

35

36

37

 

38

39

40

41

42

43

44

 

45

46

47

48

 

49

50

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

Pin

 

 

 

 

 

 

 

 

 

 

1H

1

6H

35

11H

19

16H

37

COM1 H

7

 

 

 

 

 

 

 

 

 

 

1L

2

6L

36

11L

20

16L

38

COM1 L

8

 

 

 

 

 

 

 

 

 

 

2H

3

7H

21

12H

39

17H

23

Interlock 1

17

 

 

 

 

 

 

 

 

 

 

2L

4

7L

22

12L

40

17L

24

Interlock 1

33

 

 

 

 

 

 

 

 

 

 

3H

5

8H

41

13H

25

18H

43

GND

34

 

 

 

 

 

 

 

 

 

 

3L

6

8L

42

13L

26

18L

44

TSIL*

18

 

 

 

 

 

 

 

 

 

 

4H

9

9H

27

14H

11

19H

29

AMP 41L

47

 

 

 

 

 

 

 

 

 

 

4L

10

9L

28

14L

12

19L

30

AMP 41I

48

 

 

 

 

 

 

 

 

 

 

5H

13

10H

45

15H

31

20H

15

AMP 42L

49

 

 

 

 

 

 

 

 

 

 

5L

14

10L

46

15L

32

20L

16

AMP 42I

50

 

 

 

 

 

 

 

 

 

 

Bank 2

*TSIL represents Temperature Sensor Interface Line. This line is used for temperature interface only.

WARNING As a safety feature, interlock 2 pins (17 and 33) on Bank 2 must be shorted to enable the Bank 2 Analog Bus relays to close. The optional 34921T terminal block shorts these pins for you. This feature protects inadvertent routing of high voltages from the Analog Bus to the D-sub connector of the module.

 

 

 

 

 

 

COM COM

 

 

 

 

 

 

 

 

 

 

21H

21L

22H

22L

23H

23L

2H

 

2L

24H

24L

34H

34L

25H

25L

40H

40L Interlock 2

1

2

3

4

5

6

7

 

8

9

 

10

11

12

13

14

15

16

17

TSIL* 31H 31L 27H 27L 37H

37L 33H 33L

29H 29L 39H 39L 35H 35L Interlock 2

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMP AMP AMP AMP

GND

26H

26L

36H

36L

32H

32L

28H

28L

38H

38L

30H

30L

43L

43I

44L

44I

34

35

36

37

38

39

40

 

41

42

 

43

44

45

46

47

48

49

50

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

Pin

 

 

 

 

 

 

 

 

 

 

21H

1

26H

35

31H

19

36H

37

COM2 H

7

 

 

 

 

 

 

 

 

 

 

21L

2

26L

36

31L

20

36L

38

COM2 L

8

 

 

 

 

 

 

 

 

 

 

22H

3

27H

21

32H

39

37H

23

Interlock 2

17

 

 

 

 

 

 

 

 

 

 

22L

4

27L

22

32L

40

37L

24

Interlock 2

33

 

 

 

 

 

 

 

 

 

 

23H

5

28H

41

33H

25

38H

43

GND

34

 

 

 

 

 

 

 

 

 

 

23L

6

28L

42

33L

26

38L

44

TSIL*

18

 

 

 

 

 

 

 

 

 

 

24H

9

29H

27

34H

11

39H

29

AMP 43L

47

 

 

 

 

 

 

 

 

 

 

24L

10

29L

28

34L

12

39L

30

AMP 43I

48

 

 

 

 

 

 

 

 

 

 

25H

13

30H

45

35H

31

40H

15

AMP 44L

49

 

 

 

 

 

 

 

 

 

 

25L

14

30L

46

35L

32

40L

16

AMP 44I

50

 

 

 

 

 

 

 

 

 

 

34980A User’s Guide

105

Page 117
Image 117
Agilent Technologies Switch/Measure manual 34921A D-Sub Connectors, Bank