5Matrix Switch Modules

34933A D-Sub Connectors for One-Wire Mode

Matrices 1 and 2

Matrices 1 & 2

Matrices 3 & 4

For orientation, the D-sub connector end of the module is facing you.

 

 

1C4

2C4

 

 

 

1C5

2C5

1C5

2C5

 

 

 

 

 

 

 

1C7

2C7

 

1C4

2C4 bypass bypass

1R4

2R4

 

bypass bypass

NC

NC

1C7

2C7

 

bypass bypass

NC

1

2

3

4

5

6

 

7

8

9

10

 

11

12

13

14

 

 

15

16

17

NC

1C3

2C3

1C1

 

2C1

1C2

2C2

 

1C6

2C6

1R2

2R2

1C8

 

2C8

NC

NC

GND

 

bypass bypass bypass bypass

bypass bypass

 

 

18

19

20

21

 

22

23

24

 

25

26

27

28

29

 

30

31

 

32

33

 

NC

1C3

2C3

1C1

2C1

1R3

 

2R3

1C6

2C6

1C2

 

2C2

NC

NC

1C8

 

 

2C8

1R1

2R1

 

bypass bypass

bypass

bypass

34

35

36

37

38

39

 

40

41

42

43

 

44

45

46

47

 

 

48

49

50

NOTE: Conventions for these drawings and tables as they relate to pinout information:

2R4 means Matrix 2, Row

4.

1C5 means Matrix 1, Column 5

4C2 bypass means: Matrix

4, Column 2, and the

connection bypasses the 100in-rush resistor that

protects the reed relays

Description

Pin

Description

Pin

Description

Pin

Description

Pin

Description

 

Pin

1R1

49

1C2

23

1C7

13

1C4 bypass

3

GND

 

33

 

 

 

 

 

 

 

 

 

 

1R2

27

2C2

24

2C7

14

2C4 bypass

4

No connect pins:

 

 

 

 

 

 

 

 

11-12, 17-18,

 

 

1R3

39

1C3

35

1C8

29

1C5 bypass

9

 

 

 

 

 

 

 

 

 

 

31-32, 34, and

 

1R4

5

2C3

36

2C8

30

2C5 bypass

10

 

45-46

 

 

 

 

 

 

 

 

 

 

 

 

2R1

50

1C4

1

1C1 bypass

21

1C6 bypass

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2R2

28

2C4

2

2C1 bypass

22

2C6 bypass

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2R3

40

1C5

7

1C2 bypass

43

1C7 bypass

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2R4

6

2C5

8

2C2 bypass

44

2C7 bypass

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1C1

37

1C6

41

1C3 bypass

19

1C8 bypass

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2C1

38

2C6

42

2C3 bypass

20

2C8 bypass

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Matrices 3 and 4

 

 

3C4

4C4

 

 

 

 

3C5

4C5

 

 

 

 

3C7

 

4C7

 

3C4

4C4 bypass bypass

3R4

4R4

3C5

4C5 bypass

bypass

NC

NC

3C7

4C7

bypass bypass

Interlock

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

16

17

 

3C3

4C3

3C1

4C1

 

 

3C6

4C6

 

 

 

 

 

 

 

 

NC

bypass bypass bypass bypass 3C2

4C2

bypass bypass 3R2

4R2

3C8

4C8

NC

NC

Interlock

18

19

20

21

22

23

24

25

26

27

28

29

 

30

31

32

 

33

NC

3C3

4C3

3C1

4C1

3R3

4R3

3C6

4C6

3C2

4C2

NC

NC

3C8

4C8

 

3R1

4R1

bypass bypass

bypass

bypass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

 

49

50

WARNING As a safety feature, interlock pins (17 and 33) must be shorted to enable the Analog Bus relays, which are on Matrix 2, to close. The optional 34933T-002 (for 1-wire) terminal block shorts these pins for you. This safety feature protects inadvertent routing of high voltages from the Analog Buses to the D-sub connector of the module.

Description

Pin

Description

Pin

Description

Pin

Description

Pin

 

Description

Pin

 

 

 

 

 

 

 

 

 

 

 

3R1

49

3C2

23

3C7

13

3C4 bypass

3

 

Interlock

17

 

 

 

 

 

 

 

 

 

 

 

3R2

27

4C2

24

4C7

14

4C4 bypass

4

 

Interlock

33

 

 

 

 

 

 

 

 

 

 

 

3R3

39

3C3

35

3C8

29

3C5 bypass

9

No connect pins:

 

 

 

 

 

 

 

 

 

11-12, 18, 31-32, 34,

3R4

5

4C3

36

4C8

30

4C5 bypass

10

 

 

 

 

 

 

 

 

 

 

and 45-46

 

4R1

50

3C4

1

3C1 bypass

21

3C6 bypass

25

 

 

 

 

 

 

 

 

 

 

 

 

 

4R2

28

4C4

2

4C1 bypass

22

4C6 bypass

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4R3

40

3C5

7

3C2 bypass

43

3C7 bypass

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4R4

6

4C5

8

4C2 bypass

44

4C7 bypass

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3C1

37

3C6

41

3C3 bypass

19

3C8 bypass

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4C1

38

4C6

42

4C3 bypass

20

4C8 bypass

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

160