Allied Telesis AT-S111, AT-GS950/48PS manual 256

Models: AT-S111 AT-GS950/48PS

1 386
Download 386 pages 5.61 Kb
Page 256
Image 256

Chapter 19: RMON

Falling Threshold: This parameter specifies a specific value or threshold level of the monitored statistic. When the value of the monitored statistic becomes less than this threshold level, an alarm event is triggered. The parameter’s range is 1 to 2147483647.

Rising Event Index: This parameter specifies the event index for the rising threshold. Its range is 1 to 65535. This field is mandatory and must match an Event Index that you previously entered in “Events” on page 252.

Falling Event Index: This parameter specifies the event index for the falling threshold. Its range is 1 to 65535. This field is mandatory and must match an Event Index that you previously entered in “Events” on page 252.

Owner: This parameter is used to identify the person who created an entry. It is primarily intended for switches that are managed by more than one person, and is an optional field.

4.Once you have configured the parameters, click Apply.

Your entry appears in the table at the bottom of the page. See Figure 104.

Figure 104. RMON Alarm Configuration Example Page (To be provided)

5.If you want to configure additional RMON alarms, repeat steps 3 and 4.

6.From the main menu on the left side of the page, select Save Configuration to Flash to permanently save your changes.

256

Page 256
Image 256
Allied Telesis AT-S111, AT-GS950/48PS manual 256