3.Enter a number in the Policy Index field.

The Policy Index is a unique number within the range of 1 - 65535 which identifies the policy. This field is mandatory.

4.Enter data in the remaining parameters. All parameters listed below must be entered to form the policy:

Classifier Index - Classifier table The Classifier Index is a unique number within the range of 1 - 65535. This field is mandatory. It must match one of the Classifier Indexes that you have previously defined. All defined Classifier Indexes appear in the Classifier table at the bottom of the Create Classifier page. See Figure 77 on page 221 for an example of the Classifier table .

Policy Sequence - The Policy Sequence field is a unique number within the range of 1 - 64. This field is mandatory. It identifies the ranking of the specific policy and defines when it will be executed relative to the other policies . A policy with a Policy Sequence number 1 will be executed first, number 2 will be executed second, etc. until the highest Policy Sequence number is reached which will be executed last. For the status of the order of the policies applied to specific ports, see “Policy Sequence Status” on page 243.

In-Profile Action Index - The In-Profile Action Index is a unique number within the range of 1 - 65535. This field is mandatory and must match an In-Profile Action Index that has been previously defined on the Create In-Profile Action page. See the In-Profile Action table described in “Creating an In-Profile Action” on page 227 for more information.

Out-Profile Action Index - The Out-Profile Action Index is a unique number within the range of 1 - 65535. This field is mandatory and must match an Out-Profile Action Index that has been previously defined on the Out-Profile Action page. See the Out-Profile Action table in “Creating a Out-Profile Action” on page 231 for more information.

Port List Index - The Port List Index is a unique number within the range of 1 - 65535. This field is mandatory and must match a Port List Index that has been previously entered on the Create Port List page. See the Port List table “Create Port List” on page 235 for more information.

5.Click Add.

The Policy entry is added to the status table. If you do not see your new entry, you may need to navigate to another page of the table with the First Page, Previous Page, Next Page, and Last Page buttons located below the table. An example of a Policy table entry is displayed in Figure 92 on page 240.