Installation

2.6 Cubicle mounting and connection

Mounting of the left and right cubicles

Gusset plates have been fitted to the top corners on all four sides of the cubicles to provide reinforcement for transportation.

prior to joining the two cubicles, remove the rear gusset from the right side of the left cubicle;

move the cubicles to their operating location;

adjust the front foot pads so that the cubicles are vertical and their doors aligned;

remove the top panel on the left side of the right cubicle for access to the side gussets (see figure opposite);

remove the rear double gusset on the right cubicle, turn it around and bolt the two cubicles together.

right cubicle

A

double gusset

to be

turned around

B

34006451EN/AC - Page 17