Instruction book
7.12 SF6-15  Multi 8 bar 50 Hz 1)
| Compressor type | 
 | SF6 | SF8 | SF11 | SF15 | 
| 
 | 
 | 8 bar | 8 bar | 8 bar | 8 bar | 
| Maximum working pressure for SF Pack | bar(e) | 8 | 8 | 8 | 8 | 
| Maximum working pressure for SF  | bar(e) | 7.75 | 7.75 | 7.75 | 7.75 | 
| Nominal working pressure | bar(e) | 7 | 7 | 7 | 7 | 
| Air temperature at outlet valve for SF Pack, approx. | °C | 26 | 28 | 30 | 32 | 
| Air temperature at outlet valve for SF  | °C | 23 | 25 | 25 | 25 | 
| Motor shaft speed | r/min | 2885 | 2885 | 2885 | 2885 | 
| Shaft input | kW | 5.6 | 6.9 | 10.4 | 13.8 | 
| Sound pressure level | dB(A) | 61 | 62 | 60 | 63 | 
| For SF  | 
 | 
 | 
 | 
 | 
 | 
| Refrigerant type | 
 | R134a | R134a | R134a | R134a | 
| Pressure dewpoint, approx 2) | °C | 3 | 3 | 3 | 3 | 
7.13 SF6-15  Multi 10 bar 50 Hz 1)
| Compressor type | 
 | SF6 | SF8 | SF11 | SF15 | 
| 
 | 
 | 10 bar | 10 bar | 10 bar | 10 bar | 
| Maximum working pressure for SF Pack | bar(e) | 10 | 10 | 10 | 10 | 
| Maximum working pressure for SF  | bar(e) | 9.75 | 9.75 | 9.75 | 9.75 | 
| Nominal working pressure for SF Pack | bar(e) | 10 | 10 | 10 | 10 | 
| Nominal working pressure for SF  | bar(e) | 9.75 | 9.75 | 9.75 | 9.75 | 
| Air temperature at outlet valve for SF Pack, approx. | °C | 26 | 28 | 30 | 32 | 
| Air temperature at outlet valve for SF  | °C | 25 | 25 | 25 | 25 | 
| Motor shaft speed | r/min | 2885 | 2885 | 2885 | 2885 | 
| Shaft input | kW | 5.9 | 7.5 | 11.3 | 15.0 | 
| Sound pressure level | dB(A) | 61 | 62 | 60 | 63 | 
| For SF  | 
 | 
 | 
 | 
 | 
 | 
| Refrigerant type | 
 | R134a | R134a | R134a | R134a | 
| Pressure dewpoint, approx. 2) | °C | 3 | 3 | 3 | 3 | 
7.14 SF6-15  Multi 100 psi 60 Hz 1)
| Compressor type | 
 | SF6 | SF8 | SF11 | SF15 | 
| 
 | 
 | 100 psi | 100 psi | 100 psi | 100 psi | 
| Maximum working pressure for SF Pack | bar(e) | 8 | 8 | 8 | 8 | 
| Maximum working pressure for SF  | bar(e) | 7.75 | 7.75 | 7.75 | 7.75 | 
| Nominal working pressure | bar(e) | 7 | 7 | 7 | 7 | 
| Air temperature at outlet valve for SF Pack, | °C | 26 | 28 | 29 | 30 | 
| approx. | 
 | 
 | 
 | 
 | 
 | 
| Air temperature at outlet valve for SF Full- | °C | 23 | 25 | 25 | 25 | 
| Feature, approx. | 
 | 
 | 
 | 
 | 
 | 
| Motor shaft speed | r/min | 3495 | 3495 | 3495 | 3495 | 
| Shaft input SF Pack | kW | 5.7 | 7.1 | 10.7 | 14.2 | 
| Shaft input SF  | kW | 5.8 | 7.2 | 10.8 | 14.4 | 
| Sound pressure level | dB(A) | 61 | 62 | 60 | 63 | 
| For SF  | 
 | 
 | 
 | 
 | 
 | 
| Refrigerant type | 
 | R134a | R134a | R134a | R134a | 
| Pressure dewpoint, approx 2) | °C | 3 | 3 | 3 | 3 | 
| 2920 1521 00 | 39 | 