Instruction book
6 PROBLEM SOLVING
Before carrying out any maintenance or repair:
1.Stop the compressor, switch off the voltage and open the isolating switch.
2.Close the air outlet valve 
| 1 | Compressor does not start | 
| a | Loose connection | 
| a | Have electrical connections checked | 
| b | Receiver pressure too high | 
| b | Compressor will start when the net pressure drops to the minimum pressure | 
| 2 | Safety valve blows | 
| a | Safety valve opens too soon | 
| a | Replace valve | 
| 
 | 
 | 
| 3 | Compressor capacity or pressure below normal | 
| a | Air consumption exceeds capacity of compressor | 
| a | Check equipment connected | 
| b | Choked air filter | 
| b | Remove and check filter. Replace if necessary | 
| c | Safety valve leaking | 
| c | Replace valve | 
| d | Drive belt(s) slipping | 
| d | Check condition of belt(s). Correct or replace as required | 
| 
 | 
 | 
| 4 | Compressor module overheating / compressor shut down by its air temperature switch | 
| a | Insufficient compressor cooling | 
| a | Improve ventilation of compressor room. | 
| b | Cooling fan out of order | 
| b | Check and correct | 
| 
 | 
 | 
| 
 | On SF  | 
| 
 | 
 | 
| 5 | Pressure dewpoint too high | 
| a | Shortage of refrigerant | 
| a | Have circuit repaired or recharged | 
| b | Refrigerant compressor does not run | 
| b | See 7 | 
| c | Condenser pressure is too high | 
| c | See 6 | 
| 
 | 
 | 
| 6 | Condenser pressure too high or too low | 
| a | Fan control switch out of order | 
| a | Have switch replaced | 
| b | Condenser fan motor out of order | 
| b | Have fan motor inspected | 
| c | Ambient temperature too high | 
| c | Improve ventilation. If necessary, draw the cooling air from a cooler room | 
| d | Condenser externally clogged | 
| d | Clean condenser | 
| 
 | 
 | 
| 7 | Motor of refrigerant compressor stops or does not start | 
| a | Thermal protection of the motor has tripped | 
| a | Compressor will restart when the motor windings have cooled down | 
| 2920 1521 00 | 34 | 