Instruction book

8.15 Programmable settings

8.15.1 Regulation settings

 

 

Minimum

Nominal

Maximum

 

 

setting

setting

setting

 

 

 

 

 

Number of motor starts

starts/day

240

720

720

Minimum stop time 1)

sec

5

5

30

Stop between 2 compressor

sec

2

2

5

modules

 

 

 

 

Start between 2 compressor

sec

2

2

10

modules

 

 

 

 

Power recovery time 3)

sec

10

10

3600

Delay at restarting after

sec

0

0

1200

power recovery 3)

 

 

 

 

 

 

 

 

 

Minimum pressure 2)

 

 

 

 

8 bar Pack

bar(e)

4

7

7.9

8 bar Full-Feature

bar(e)

4

6.8

7.7

10 bar Pack

bar(e)

4

9

9.9

10 bar Full-Feature

bar(e)

4

8.8

9.7

100 psi Pack

bar(e)

4

7

7.9

100 psi Full-Feature

bar(e)

4

6.8

7.7

125 psi Pack

bar(e)

4

8.1

9

125 psi Full-Feature

bar(e)

4

7.75

8.8

145 psi Pack

bar(e)

4

9

9.9

145 psi Full-Feature

bar(e)

4

8.8

9.7

 

 

 

 

 

Maximum pressure 2)

 

 

 

 

8 bar Pack

bar(e)

4.1

8

8

8 bar Full-Feature

bar(e)

4.1

7.8

7.8

10 bar Pack

bar(e)

4.1

10

10

10 bar Full-Feature

bar(e)

4.1

9.8

9.8

100 psi Pack

bar(e)

4.1

8

8

100 psi Full-Feature

bar(e)

4.1

7.8

7.8

125 psi Pack

bar(e)

4.1

9.1

9.1

125 psi Full-Feature

bar(e)

4.1

8.9

8.9

145 psi Pack

bar(e)

4.1

10

10

145 psi Full-Feature

bar(e)

4.1

9.8

9.8

 

 

 

 

 

For Full-Feature also 4)

 

 

 

 

Dewpoint warning

°C

3

15

40

temperature

 

 

 

 

Delay at signal 5)

sec

0

3

10

Delay at starting 6)

sec

0

255

255

2920 1521 00

64

Page 64
Image 64
Atlas Air Compressor manual Programmable settings, Regulation settings Minimum Nominal Maximum Setting