Instruction book
8.15 Programmable settings
8.15.1 Regulation settings
|
| Minimum | Nominal | Maximum | |
|
| setting | setting | setting | |
|
|
|
|
| |
Number of motor starts | starts/day | 240 | 720 | 720 | |
Minimum stop time 1) | sec | 5 | 5 | 30 | |
Stop between 2 compressor | sec | 2 | 2 | 5 | |
modules | |||||
|
|
|
| ||
Start between 2 compressor | sec | 2 | 2 | 10 | |
modules | |||||
|
|
|
| ||
Power recovery time 3) | sec | 10 | 10 | 3600 | |
Delay at restarting after | sec | 0 | 0 | 1200 | |
power recovery 3) | |||||
|
|
|
| ||
|
|
|
|
| |
Minimum pressure 2) |
|
|
|
| |
8 bar Pack | bar(e) | 4 | 7 | 7.9 | |
8 bar | bar(e) | 4 | 6.8 | 7.7 | |
10 bar Pack | bar(e) | 4 | 9 | 9.9 | |
10 bar | bar(e) | 4 | 8.8 | 9.7 | |
100 psi Pack | bar(e) | 4 | 7 | 7.9 | |
100 psi | bar(e) | 4 | 6.8 | 7.7 | |
125 psi Pack | bar(e) | 4 | 8.1 | 9 | |
125 psi | bar(e) | 4 | 7.75 | 8.8 | |
145 psi Pack | bar(e) | 4 | 9 | 9.9 | |
145 psi | bar(e) | 4 | 8.8 | 9.7 | |
|
|
|
|
| |
Maximum pressure 2) |
|
|
|
| |
8 bar Pack | bar(e) | 4.1 | 8 | 8 | |
8 bar | bar(e) | 4.1 | 7.8 | 7.8 | |
10 bar Pack | bar(e) | 4.1 | 10 | 10 | |
10 bar | bar(e) | 4.1 | 9.8 | 9.8 | |
100 psi Pack | bar(e) | 4.1 | 8 | 8 | |
100 psi | bar(e) | 4.1 | 7.8 | 7.8 | |
125 psi Pack | bar(e) | 4.1 | 9.1 | 9.1 | |
125 psi | bar(e) | 4.1 | 8.9 | 8.9 | |
145 psi Pack | bar(e) | 4.1 | 10 | 10 | |
145 psi | bar(e) | 4.1 | 9.8 | 9.8 | |
|
|
|
|
| |
For |
|
|
|
| |
Dewpoint warning | °C | 3 | 15 | 40 | |
temperature | |||||
|
|
|
| ||
Delay at signal 5) | sec | 0 | 3 | 10 | |
Delay at starting 6) | sec | 0 | 255 | 255 |
2920 1521 00 | 64 |