Instruction book

8.9.2 Modifying protections for Dryer LAT on Full-Feature machines

1. Consult the section above to select the parameter Dryer LAT (Low Ambient Temperature):

Dryer LAT

 

10 °C

Warning

Maximum

25 °C

Back

Modify

 

 

F1

F2

F3

 

Fig. 8.14 Modify parameters menu

2.The screen shows that the Dryer LAT is 10 °C and that the shut-down setting is 25 °C. To modify this setting, press the key "Modify" (F2):

Dryer LAT

 

10 °C

Warning

Maximum

25 °C

Program

Limits

Cancel

F1

F2

F3

Fig. 8.15 Modify parameters menu

3.The key "Limits" (F2) can be used to find the limitations for the parameter. Use the ↓ or ↑ arrow key to change the value.

4.Press the key "Program" (F1) to program the new setting or the key "Cancel" (F3) to cancel the modification operation.

Note:

The modifying procedure for other settings is similar. For some settings, a delay can be programmed. See section 8.15.

8.10 Modifying service plans

Function

To modify the hour intervals for the Service plans.

Service plans

The service operations to be carried out are grouped in plans, called Service plan A, B, D or I. When reaching an interval, a message will appear on the screen indicating which Service plans are to be carried out.