3. Press the tabulator key (5):
Next Timer |
|
|
|
Level |
| ABI |
|
|
| 10000 hrs | ↓ |
Back |
| Reset |
|
F1 | F2 | F3 |
|
| Fig. 8.20 Service menu, typical example |
|
|
The screen shows that the next service plans to be carried out are plans A, B and I and that these plans are to be carried out each 10000 running hours.
4. Press the ↓ key to find which service plans were carried out previously:
Previous Timer |
| ↑ |
Level |
| AI |
Back |
| 5008 hrs |
|
| |
F1 | F2 | F3 |
| Fig. 8.21 Service menu, typical example |
|
The screen shows that service plans A and I were carried out at 5008 running hours.
5.Stop the compressor, switch off the voltage and carry out the service operations related to plans A, B and I.
6.Switch on the voltage and scroll to the service screen shown in Fig. 8.20. Press the "Reset" button (F3) to reset the timer. Confirm the question for resetting.
Notes
-The "Reset" button only appears when the next Timer level is almost reached (from 400 running hours before elapsing of the service plan interval).
-After pressing the ↓ key in Fig. 8.19, the Life time hours are shown (i.e. the number of hours elapsed since initial programming ex-factory). This counter is not taken into account.