8.7 Modify parameters menu

Function

The menu allows the operator to program:

-Parameters, see section 8.8.

-Protections settings, see section 8.9.

-Service plan settings, see section 8.10.

-Clock function settings, see section 8.11.

-Configuration settings, see section 8.12.

8.8 Modifying parameters

Function

To modify a number of parameters as mentioned below and in Fig. 8.1.

-Pressure Band 1 High

-Pressure Band 1 Low

-Pressure Band 2 High

-Pressure Band 2 Low

-Number Of Starts/Day (per compressor module)

-Minimum Stop Time (i.e. the time period during which the compressor, if stopped automatically, remains stopped whatever happens with the air net pressure)

-Power recovery time (if automatic restart after voltage failure is activated) 3)

-Restart delay (can be programmed, allowing e.g. compressors to be restarted one after the other)

-Time to next start (time between the starting of two compressor modules)

-Time to next stop (time between the stopping of two compressor modules during regulation)

Procedure

1.Starting from the Main screen (see section 8.1.2):

-press the key "Menu" (F1)

-press the ↓ key until the option "Modify Parameters" is followed by a horizontal arrow

-press the tabulator key (5) to activate the menu

2.The first option ("Parameters") will be followed by a horizontal arrow.

3.Press the tabulator key (5): the first item ("Pressure Band 1 High") and its setting will appear.

4.Use the ↓ key to scroll until the parameter to be modified is followed by a horizontal arrow.

2920 1521 00