Instruction book
1.5.6 Display – keys
Compressor Outlet |
| 7.0 bar |
Compressor Running |
| ↓ |
Menu |
| - - - - |
F1 | F2 | F3 |
Fig. 1.12 Typical example of a display
Operating condition of a compressor module
The symbols shown above key F3 indicate the operating condition of each control module, see also section 8.1.2:
Symbol | Indicates | |
| that the compressor module is available (ready to run), each | |
- | symbol stands for a compressor module (the left symbol stands for | |
the lowest mounted module, the right symbol stands for the | ||
| ||
| highest module) | |
▄ | that the compressor module is running | |
- (blinking) | that the compressor module is not available (due to minimum stop | |
time or too many starts) | ||
| ||
* (blinking) | that the compressor module is |
Scroll keys (3-Fig. 1.11)
These keys, labelled with vertical arrows, allow to scroll through the display.
As long as a downwards pointing arrow is shown at the utmost right position of the display, the key (3) with the same symbol can be used to see the next item.
As long as an upwards pointing arrow is shown at the utmost right position of the display, the key (3) with the same symbol can be used to see the previous item.
Tabulator key (4-Fig. 1.11)
This key, labelled with two horizontal arrows, allows the operator to go to the next field of the display, e.g. during modifying of programmable parameters.
1.5.7 Function keys (5-Fig. 1.11)
The keys are used:
-To call up or program settings
-To reset an active
-To have access to all data collected by the regulator
The function keys allow to make the required selection from a menu of possibilities. The functions of the keys vary depending on the displayed menu. The actual function is abbreviated and indicated on the bottom line of the display just above the relevant key. Only the active and relevant functions at a moment are shown:
Designation | Function |
Back | To return to a previously shown option or menu |
Cancel | To cancel a programmed setting when programming parameters |
Delete | To delete compressor start/stop commands |
Extra | To find the module configuration of the regulator |
Help | To find the Atlas Copco internet address |
Limits | To show limits for a programmable setting |
Mainscreen | To return from a menu to the main screen |
2920 1521 00 | 13 |