2.3 Electrical connections

General

The electrical installation must correspond to the local codes. The mains supply and earthing lines must be of suitable size. See section 7.1.

The installation must be earthed and protected by fuses in each phase. An isolating switch must be installed near the compressor. Make sure that this switch is open to isolate the compressor from the mains before carrying out any connection.

Connections

Skid - Tank-mounted - Twin

Connect the cable to terminals 1 and 3 (single-phase) or to terminals 1, 3 and 5 (3-phase) of pressure switch (4-Fig. 1.10). Connect the earthing conductor to the earthing terminal. SF Twin have a pressure switch for each compressor module; provide for each pressure switch separate supply cables.

(1)

(1)

 

9820 3744 60

9820 3744 61

55104D

55103D

 

Single-phase

3-phase

Fig. 2.7 Service diagram, SF Skid - Tank-mounted – Twin

Text on Fig. 2.7

(1) Customer’s installation

2920 1521 00

24