4. Press the tabulator key (5): a screen similar to the one below will appear:
Service Timer |
|
|
|
Level |
| A |
|
Menu | Modify | 5000 hrs | ↓ |
|
| ||
F1 | F2 | F3 |
|
Fig. 8.17 Service plan menu
5.The screen indicates that the level for Service plan A is set at 5000 running hours.
6.Press the "Modify" key. The key "Limits" (F2) can be used to find the limitations for the parameter. Use the ↓ or ↑ arrow key to modify the interval.
7.Press the key "Program" (F1) to program the new setting or the key "Cancel" (F3) to cancel the modification operation.
8.The procedure to modify the Service plans B, D and I are carried out in a similar way. Press the ↓ key in Fig. 8.17 to find the other Service plans.
8.11 Programming Clock function
To program:
-
-
8.11.1 Programming start/stop/pressure band commands
In this example, the compressor will be programmed as follows:
-On Monday at 06:15 starting in pressure band 1
-On Friday at 18:00 changing over to pressure band 2
-On Saturday at 18:00 stopping
1.Starting from the Main screen (see section 8.1.2):
-press the key "Menu" (F1)
-press the ↓ key until the option "Modify parameters" is followed by a horizontal arrow
-press the tabulator key (5) to activate the menu
2.Use the ↓ key to scroll until the option "Clock function" is followed by a horizontal arrow. Press the tabulator key (5), following screen appears:
Clock Function
|
| Not activated → |
Menu | Modify | Delete |
F1 | F2 | F3 |
2920 1521 00 | 54 |