5.3 Host Commands
At command issuance (I/O registers setting contents)
1F7H(CM) | 1 | 1 | 0 | 0 | 0 | 1 | 1 | 0 |
1F6H(DH) | × | × | × | DV | xx |
|
|
|
|
|
|
|
|
|
|
|
|
1F5H(CH) | xx |
|
|
|
|
|
|
|
1F4H(CL) | xx |
|
|
|
|
|
|
|
1F3H(SN) | xx |
|
|
|
|
|
|
|
1F2H(SC) | Sector count/block |
|
|
|
|
| ||
1F1H(FR) | xx |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
At command completion (I/O registers contents to be read)
1F7H(ST) | Status information |
|
| ||
|
|
|
|
|
|
1F6H(DH) | × | × | × | DV | xx |
|
|
|
|
|
|
1F5H(CH) | xx |
|
|
|
|
1F4H(CL) | xx |
|
|
|
|
1F3H(SN) | xx |
|
|
|
|
1F2H(SC) | Sector count/block |
|
| ||
1F1H(ER) | Error information |
|
| ||
|
|
|
|
|
|
After
The mode established before software reset is retained if disable default (Features Reg. = 66h setting) has been defined by the SET FEATURES command. If disable default has not been defined after the software is the READ MULTIPLE and WRITE MULTIPLE commands are disabled.
The parameters for the multiple commands which are posted to the host system when the IDENTIFY DEVICE command is issued are listed below. See Subsection 5.32 for the IDENTIFY DEVICE command.