Interface

Figure 5.2 Execution example of READ MULTIPLE command

At command issuance (I/O registers setting contents)

1F7H(CM)

1

1

0

0

0

1

0

0

 

 

 

 

 

 

1F6H(DH)

×

L

×

DV

Start head No. /LBA [MSB]

 

 

 

 

 

 

 

 

 

1F5H(CH)

Start cylinder No. [MSB] / LBA

 

 

 

1F4H(CL)

Start cylinder No. [LSB] / LBA

 

 

 

1F3H(SN)

Start sector No. / LBA [LSB]

 

 

 

1F2H(SC)

Transfer sector count

 

 

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

 

 

 

 

 

 

 

 

1F7H(ST)

Status information

 

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

DV

End head No. /LBA [MSB]

 

 

 

 

 

 

 

 

 

1F5H(CH)

End cylinder No. [MSB] / LBA

 

 

 

1F4H(CL)

End cylinder No. [LSB] / LBA

 

 

 

1F3H(SN)

End sector No. / LBA [LSB]

 

 

 

1F2

H

(SC)

00(*1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F1H(ER)

Error information

 

 

 

 

 

*1 If the command is terminated due to an error, the remaining number of sectors for which data was not transferred is set in this register.

5-20

C141-E088-01EN

Page 93
Image 93
Fujitsu MHK2090AT, MHK2120AT, MHK2060AT, MHJ2181AT manual Execution example of Read Multiple command