Interface

Check sum

Two’s complement of the lower byte, obtained by adding 511-byte data one byte at a time from the beginning.

Insurance failure threshold

The limit of a varying attribute value. The host compares the attribute values with the thresholds to identify a failure.

If an unrecoverable error is detected during execution of a command received by the device from the host computer, the device saves the SMART error log on the disk medium.

The host computer can issue the SMART Read Log Sector sub-command (FR register = D5h, SN register = 01h) and read the SMART error log.

Table 5.10 SMART error log data format (1/2)

Byte

 

 

 

Item

 

 

 

 

 

00

Error log version number

 

 

 

 

 

 

 

 

01

Error log index

 

 

 

 

 

 

 

 

 

02

Error log 1

 

Command Data 1

 

Device Control register

 

 

 

 

 

 

03

 

 

 

 

Features register

 

 

 

 

 

 

04

 

 

 

 

Sector Count register

 

 

 

 

 

 

05

 

 

 

 

Sector Number register

 

 

 

 

 

 

06

 

 

 

 

Cylinder Low register

 

 

 

 

 

 

07

 

 

 

 

Cylinder High register

 

 

 

 

 

 

08

 

 

 

 

Device/Head register

 

 

 

 

 

 

09

 

 

 

 

Command register

 

 

 

 

 

 

0A to 0D

 

 

 

 

Elapsed time [ms] from the

 

 

 

 

 

point when the power is turned

 

 

 

 

 

on until command reception

 

 

 

 

 

0E to 3D

 

 

Command Data 2 to 5

(The format of each type of

 

 

 

 

 

command data is the same as

 

 

 

 

 

that of byte 02 to 0D.)

 

 

 

 

 

 

3E

 

 

Error data

 

Reserved

 

 

 

 

 

 

3F

 

 

 

 

Error register

 

 

 

 

 

 

40

 

 

 

 

Sector Count register

 

 

 

 

 

 

41

 

 

 

 

Sector Number register

 

 

 

 

 

 

42

 

 

 

 

Cylinder Low register

 

 

 

 

 

 

43

 

 

 

 

Cylinder High register

 

 

 

 

 

 

5-66

C141-E088-01EN

Page 139
Image 139