7.15 SF6-15  Multi 125 psi 60 Hz 1)
| Compressor type | 
 | SF6 | SF8 | SF11 | SF15 | 
| 
 | 
 | 125 psi | 125 psi | 125 psi | 125 psi | 
| Maximum working pressure for SF Pack | bar(e) | 9.1 | 9.1 | 9.1 | 9.1 | 
| Maximum working pressure for SF  | bar(e) | 8.85 | 8.85 | 8.85 | 8.85 | 
| Nominal working pressure | bar(e) | 8.6 | 8.6 | 8.6 | 8.6 | 
| Air temperature at outlet valve for SF Pack, approx. | °C | 26 | 28 | 30 | 30 | 
| Air temperature at outlet valve for SF  | 
 | 23 | 25 | 25 | 25 | 
| approx. | 
 | 
 | 
 | 
 | 
 | 
| Motor shaft speed | 
 | 3505 | 3505 | 3505 | 3505 | 
| Shaft input for SF Pack | kW | 5.8 | 7.4 | 11.0 | 14.7 | 
| Shaft input for SF  | kW | 5.9 | 7.4 | 11.1 | 14.8 | 
| Sound pressure level | dB(A) | 61 | 62 | 60 | 63 | 
| For SF  | 
 | 
 | 
 | 
 | 
 | 
| Refrigerant type | 
 | R134a | R134a | R134a | R134a | 
| Pressure dewpoint, approx. 2) | °C | 3 | 3 | 3 | 3 | 
7.16 SF6-15  Multi 145 psi 60 Hz 1)
| Compressor type | 
 | SF6 | SF8 | SF11 | SF15 | 
| 
 | 
 | 145 psi | 145 psi | 145 psi | 145 psi | 
| Maximum working pressure for SF Pack | bar(e) | 10 | 10 | 10 | 10 | 
| Maximum working pressure for SF  | bar(e) | 9.75 | 9.75 | 9.75 | 9.75 | 
| Nominal working pressure for SF Pack | bar(e) | 10 | 10 | 10 | 10 | 
| Nominal working pressure for SF  | bar(e) | 9.75 | 9.75 | 9.75 | 9.75 | 
| Air temperature at outlet valve for SF Pack, approx. | °C | 26 | 28 | 30 | 32 | 
| Air temperature at outlet valve for SF  | 
 | 23 | 25 | 25 | 25 | 
| approx. | 
 | 
 | 
 | 
 | 
 | 
| Motor shaft speed | 
 | 3505 | 3505 | 3505 | 3505 | 
| Shaft input | kW | 5.9 | 7.5 | 11.3 | 15.0 | 
| Sound pressure level | dB(A) | 61 | 62 | 60 | 63 | 
| For SF  | 
 | 
 | 
 | 
 | 
 | 
| Refrigerant type | 
 | R134a | R134a | R134a | R134a | 
| Pressure dewpoint, approx. 2) | °C | 3 | 3 | 3 | 3 | 
Footnotes chapter 7
1)At reference conditions
2)At 20 °C / 100% relative humidity
| 2920 1521 00 | 40 | 