Installation
24 Avaya CMS Sun Ultra 5 Computer Hardware Installation, Maintenance, and Troubleshooting
Electrical specifications
Note:
Note: For power integrity, an Uninterruptible Power Supply (UPS) is recommended
for all installations.
Parameter Value
Input current
- Voltage range
- Current, frequency range
- Current, maximum (120 V)
100-240 V AC, autosensing
(newer systems)
100 to 125 or 200 to 240 V AC, switch
selectable (older systems)
50-60 Hz
6A@120 V
Input power rating (total
continuous power) 200 W
Volt-ampere rating 300 VA
BTU rating 967 BTU
Wall plug type
- United States
- Non-United States NEMA 5-15P
Power cords must be obtained locally
CPU plug type IEC 320