Operators Manual
ALS 230
Stop position ___________________________________________________ STOD
Function: Stop position of the label at the dispensing edge.
Available: Always
Range: 0.0 .... 200.0 mm
Product length ___________________________________________________PRDL
Function: The product length avoids multi labelling in case of difficult products. Normally it is set to AUTO. This means that the product length is set to the label length.
After the product sensor has detected the edge of the product all signals that might be triggered while the product is passing the product sensor are inhibited. This function can be helpful in cases where the product is transparent or has several detection marks or edges. Such a case is shown below.
The product sensor supplies several signals while the product passes the product sensor. If the PRDL is not adjusted according to the dimension of the actual product the warning W_0 may be given of false multiple product detection signals. The defined product length suppresses all signals after the first product sensor signal has been received.
By pressing the keys FUNCTION the parameter PRDL is selected. The data input is selected by pressing the key ENTER.
If an applicator is fitted to the labeller, the product length is not defined as a distance but as the time that the product needs to pass the product sensor. The time is adjustable between 5 and 9999 ms.
Available: Always
Range: AUTO or 5 - 999 mm
Label position_____________________________________________________POS
Function: Position of label on the product.
Only available if no applicator is used.
Range: up to 999.9 mm in steps of 0.1 mm.
Release 11/05 | Page 37 | Menu structure |