Operators Manual
ALS 230
6.1 Handling the menu
The menu structure is shown in the following table. By means of the key PRIOR you switch to the prior function, and with the key NEXT to the next following function in the menu.
If you press the key ENTER the current parameter value of a function is shown. The current parameter value can be changed with the keys PRIOR FUNCTION or NEXT FUNCTION. Values are stored by pressing the key ENTER.
Display | Function of the parameter | Possible data entry |
DTST | Test run without labels |
|
|
|
|
P_S_ | Product sensor detects at leading or | LEDG, TEDG |
| trailing edge of product |
|
|
|
|
MACH | Machine type | 230, 720, 330, 430 |
|
|
|
MDIR | Motor running direction for left or right | |
| hand |
|
|
|
|
MLAB | Handling of missing label | NONE, WARN, ERR1, ERR2, |
|
| ERR3 |
|
|
|
APSF | Automatic product speed follower | YES, NO |
|
|
|
APPL | Direct dispense mode, or applicators | DIR, ASA, EP, RVEP |
|
|
|
I_CH | Test of inputs |
|
|
|
|
O_CH | Test of outputs |
|
|
|
|
FACT | Reset of all parameters to default values | YES, NO |
|
|
|
BAUD | Baudrate of the interface | NONE, 300 to 192% |
|
|
|
PARI | Parity bit | NO, 0PRT, ODD, EVEN |
|
|
|
SBIT | Number of Stop bits | 1 bit, 2 bit |
|
|
|
DBIT | Number of data bits | 7 bit, 8 bit |
|
|
|
RECY | Recycle (simulates max labels/min) | see text |
|
|
|
DIST | Distance label sensor to dispensing edge | 10 ... 999 mm |
|
|
|
LABC | Number of dispensed labels | see text |
|
|
|
QUIT | Return to extended standard menu |
|
|
|
|
Release 11/05 | Page 44 | Configuration |