Operators Manual
ALS 230
Command | Description | Range | |
#!MDIRnnnn | Motor direction | 0000 | Right |
|
| 0001 | Left < |
|
|
|
|
#!MLABnnnn | Missing label error | 0000 | NONE |
|
| 0001 | Warning |
|
| 0002 | Error 1 |
|
| 0003 | Error 2 |
|
|
|
|
#!PDT nnnn | Print dwell time | 0001 | – 1000 ms |
|
| 0000 printer off | |
|
|
|
|
#!PHT nnnn | Printer hold time | 0001 | – 7500 ms |
|
|
|
|
#!POS_nnn | Labelling position | 0001 | – 9999 * 0.1 mm |
|
|
|
|
#!PRDLnnnn | Product length | 0005 | – 4000 mm |
|
|
|
|
#!P_S_nnnn | Polarity product sensor | 0000 | LEDG |
|
| 0001 TEDG | |
|
|
| |
#!RAMPnnnn | Acceleration Ramp | 0000 NORM | |
|
| 0001 FAST | |
|
|
|
|
#!SLEWnnnn | Slew speed | 0000 | = FAST |
|
| 0001 | = SLOW |
|
|
|
|
#!STADnnnn | Start delay | 0001 | - 9999 ms |
|
|
|
|
#!STODnnnn | Stop position | 0080 | - 9999 * 0.1 mm |
|
|
|
|
#!VELOnnnn | Speed | 0020 | - 0300 * 0.1m/min |
|
|
|
|
#!SAVEnnnn | Store in data bank | 0001 | - 0009 |
|
|
|
|
#!LOADnnnn | Load data bank | 0001 | - 0009 |
|
|
|
|
The following described commands do not have parameter values. With these commands the host can monitor and control the machine.
#!CLRC | Set label counter to 0 |
|
#!CLRE | Clear error message |
|
#!CLRW | Clear warning |
|
#!ERRF | The machine sends an error status to the monitoring computer. The message | |
| ERR8___4__1_<04H> means, error 8, 4 and 1 have occurred. |
|
#!WARF | The machine sends a warning status to the monitoring computer. The message | |
| WARF7______0 means: The warnings 7 and 0 have occurred. |
|
#!LABC | The machine sends the number of dispensed labels e.g. LABC0000008359 back | |
#!SP__ | The machine is set to off. The product sensor is disabled and labelling will | |
| therefore be stopped. |
|
Release 11/05 | Page 53 | Serial interface |