Operators Manual

ALS 230

7. Serial interface

The machine has a serial interface according to the standard RS232C. Via this interface parameters can be adjusted. All received commands are tested for syntax and legal value range.

Invalid commands and parameters are ignored. An error message is not given in this case. All commands received over the serial interface are tested for syntax and range; invalid commands and out of range parameter values are ignored. A warning message is not given in these cases. However in the case of framing, parity or overrun errors the warning "W__3" is generated.

The commands are made up of sequences of ASCII characters. Each command starts with "#" and "!" followed by a 4 character code. The reception of the "#" character indicates the start of a new command to the machine.

The codes are similar to the parameter names shown in the display.

7.1 Data of the serial interface

The pin connection of the interface plug is shown in the table below.

Dispenser connector

 

Signal description

PC

25 pol D-

9 pol D-

Direction

Code

Description

25 pol

9 pol

Sub

Sub

 

 

 

 

 

Socket 2

3

Output

TxD

Transmit data

3

2

Socket 3

2

Input

RxD

Receive data

2

3

Socket 5

8

Input

CTS

Clear to send

4

7

Socket 4

7

Output

RTS

Request to send

5

8

Socket 7

5

 

GND

 

7

5

Socket 20

4

Output

DTR

 

6

6

Socket 24

 

(if jumper

+ 10V

For external use

8

 

 

 

on)

 

 

 

 

All other pins are not connected.

Adjustable data values

Baudrate

150, 300, 600, 1200, 2400, 4800, 9600, 19200 Baud

Data bits

7 or 8 bits

Stop bits

1 or 2 bits

Parity

No Parity, Parity bit always 0, odd or even parity

Handshake

RTS/CTS

Factory

interface deactivated, at reactivation the parameters will be set to 8 data bits, 2

 

stop bits and no parity bit.

 

 

Release 11/05

Page 51

Serial interface

Page 53
Image 53
Avery ALS 230 manual Serial interface, Data of the serial interface