8.3.2OD Control sensor

Optional an OD control could be mounted to control the label roll. If the label material is nearly empty the sensor gives an signal. A warning message and an output signal inform the personal that in the next time the material has to be changed.

NPN sensor

Supply

Signal+

Signal-

GND

 

5

5

white

brown

9

9

red

 

4

4

 

 

8

8

 

 

3

3

 

white

7

7

green

 

2

2

 

 

6

6

 

grey

1

1

black

blue

+24V

11

27

25

14

GND

E3JK-R2M2

Figure 17 NPN connection of optional ODC sensor

CN33

+24V

PNP sensor

Supply

Signal+

Signal-

GND

brown

5

5

white

 

white

9

9

red

 

4

4

 

 

8

8

 

grey

3

3

 

 

7

7

green

 

2

2

 

 

6

6

 

blue

1

1

black

11

27

25

14

GND

S5-5-C8-30

Figure 18 PNP connection of optional ODC sensor

CN33

Release 11/05

Page 62

Connections and signals

Page 64
Image 64
Avery ALS 230 manual OD Control sensor, NPN connection of optional ODC sensor