8.2 Applicator modes

The machine is able to dispense the label direct on the passing product. There is also the possibility to drive without any external control a wide range of applicators.

8.2.1Signals for direct dispense

For direct dispensing the airstream signal can be used to control a pneumatic driven dispensing edge. The start of the airstream signal (= motor run signal) could be behind the start of the dispense motor, adjusted with the function APT3. The signal is switched inactive, when the label dispense has been completed. Also the stop could be adjusted with the function ASTP to switch inactive before or behind the dispense motor stop.

Ready

Product start

Label start Suppression

1

4

3

Product start Suppression

Dispense

Motor run signal

PRDL

 

POS

 

 

 

 

POS

 

POS

 

 

 

2

 

 

APT3

ASTP

ASTP

 

 

 

1Productstart disabled. PRDL activ

2Missing Label: New start of dispense during dispenser activ

3Inhibit activ

4Machine not ready. Errorcondition or not online

Figure 10 Timing diagram direct dispense

Release 11/05