Operators Manual
ALS 230
7.2 Interface commands
The below described commands will change one of the labelling parameter. The values are not stored and will be lost when turning off power.
If the sequence nnnn is replaced by the character "?" then the current value of that parameter will be returned by the labelling machine as a 4 character string confirming the name of the parameter requested followed by 4 numbers representing the current value of that parameter. The character 04H terminates all return messages.
Example |
|
|
|
|
PC send the message: | #!VELO? |
|
| |
Machine returns: |
| VELO0300<04H> |
|
|
|
|
| ||
Command | Description | Range | ||
#!APOSnnnn | Value APOS | |||
|
|
| ||
#!APPLnnnn | Applicator type | 0000 direct dispense | ||
|
|
| 0001 ASA | |
|
|
| 0002 EP | |
|
|
| 0003 EP_U | |
|
|
| 0004 PLUA | |
|
|
| 0005 INDX | |
|
|
| ||
#!APSFnnnn | APSF function | 0000 off | ||
|
|
| 0001 on | |
|
|
|
| |
#!APT1nnnn | Applicator time | 0001 | – 7500 ms | |
|
|
|
| |
#!APT2nnnn | Applicator time | 0001 | – 7500 ms | |
|
|
|
| |
#!APT3nnnn | Applicator time | 0000 | – 5000 ms | |
|
|
| ||
#!ASTPnnnn | Value ASTP | |||
|
|
|
| |
#!BANKnnnn | Change product bank | 0000 | - 0009 | |
|
|
|
| |
#!BLOWnnnn | Blow on time = APT 2 | 0001 | - 7500 ms | |
|
|
|
| |
#!COMPnnnn | Automatic label compensation | 0000 | = Off | |
|
|
| 0001 | = On |
|
|
|
| |
#!CONTnnnn | Material contrast | 0001 | – 0200 | |
|
|
| 0000 automatically | |
|
|
|
| |
#!DISTnnnn | Distance label sensor – dispensing | 0080 | – 9999 * 0.1 mm | |
| edge |
|
|
|
#!EGRAnnn | Gear ratio | 0300 | – 1000 | |
|
|
|
| |
#!LPITnnnn | Label length | 0005 | – 0999 mm | |
|
|
| 0000 automatically | |
|
|
| ||
#!MACHnnnn | Machine type | 0000 ALS230 | ||
|
|
| 0001 ALX720 | |
|
|
| 0002 ALS330 | |
|
|
| 0003 ALS430 | |
|
|
|
|
|
Release 11/05 |
| Page 52 |
| Serial interface |