Operators Manual
ALS 230
Start delay ______________________________________________________STAD
Function: Delay time for the dispensing by means of an applicator after the product has passed the product sensor. This value influences the position of the label on the product.
Only available if applicator is used. Range: 1 to 9999 ms
Dispensing speed ________________________________________________VELO
Function: The labelling speed may be adjusted with the parameter VELO. Values between 0.2 and 30.0 m/min are possible. The speed has to be adjusted so that it matches the product speed.
When an applicator is fitted to the machine, this parameter defines how fast the label will be dispensed on to the applicator.
EGRA value check ________________________________________________ STST
Use this function to adjust the EGRA value. If the
Slew speed _____________________________________________________ SLEW
Function: For some situations the labeller can run with a different, higher speed. This occurs during compensation of a missing label on the web, positioning the label at the dispensing edge during initialisation or after pressing the feed button if the
SLEW setting | FAST | SLOW |
APSF off | Max speed | VELO |
APSF on | Max speed | 12 m/min |
Electronic gear ratio adjustment ___________________________________ EGRA
The parameter EGRA appears in the extended menu only after the APSF function has been switched on.
The range of the EGRA parameter is 100 to 500, representing from 1 to 5 encoder pulses per millimetre of conveyor movement. The full EGRA range can be used up to 30 m/min conveyor speed.
With an applicator there is no realistic limit to the conveyor speed and at very
Dwell time _______________________________________________________ APT1
Function: Only used when an EP- applicator is necessary. It defines for how long the pneumatic cylinder is switched on.
Available only with applicator. Range: 1 ... 7500 ms
Release 11/05 | Page 38 | Menu structure |