Operators Manual

ALS 230

yError display:

If the display shows e.g. E__XX, the dispenser has recognised an error. A warning is shown by W_XX. As soon as the error has been corrected, you may erase the message by pressing the key ENTER and you will get back to the status the machine was in before the error was indicated.

Note: Data entered in the standard menu are not stored, if the machine is switched off. If you need to store data you have to use the extended menu. Please check if it is of help for you using the product menu in your application.

Display

Menu function

Function data value

ON

Labeller ready

 

 

 

 

OFF

Label function suspend

 

 

 

 

POS

label position on product

Up to 999.9 mm

 

 

 

STOD

Label stop position at the

Depends on setting of DIST, Label

 

dispensing edge

length and RAMP

 

 

 

VELO

Dispensing speed

0.2 ... 30.0 m/min

 

 

 

STAD

delay time before labelling starts

0,1 ... 999,9 ms

 

 

 

BLOW

apply time

0,1 ... 999,9 ms

 

 

 

INIT

Initialisation of label material

Appears after E__0, E__1 and Power

 

(CONT and LPIT are measured

on + FEED key depressed, or if the

 

according to label size)

values of CONT and LPIT are

 

 

changed

 

 

 

Dispenser active ___________________________________________________ ON

The dispenser is able to dispense labels.

Dispenser stopped_________________________________________________ OFF

The dispenser function is stopped. Single labels could be dispensed with the FEED key.

Material initialisation _______________________________________________ INIT

A new initialisation of material is necessary. Pressing the FEED key will start the initialisation.

Label position_____________________________________________________POS

The position of the label can be changed by the parameter POS while the machine is in operation. The display is presented in 1/10 mm and means the distance between product sensor and labelling position of the product. The display value 0500 would mean 50.0 mm. By

Release 11/05

Page 27

Operation

Page 29
Image 29
Avery ALS 230 manual Dispenser active on, Dispenser stopped OFF, Material initialisation Init, Label positionPOS